Engineering AllOther (1379) what is mean by busbar and what is the difference between busbar,transmissionline,feeder,distribution line
5675I hv a question regarding power factor improvement just after transformer. I request you to reply me plzz. thank you sir. My friend has a small unit of fabrication. in his factory the main load is a welding machine, lathe machine, grinding machine. this load is not continuous type. now our electricity board has installed 16 KVA, 11000/433 V transformer for our factory. In the energy meter (trivector meter) at LV side of transformer, i hv seen power factor value of 0.15 only when only 3 KW load was flowing. Further electricity board has suggested to install 4 KVAR capacitor at LV side after energy meter. Now my question is that if we permanantly install and switch on 4 KVAR capacitor after energy meter, during some load on transformer and also without any load on transformer, wht will be the power factor shown in energy meter?i dont want to get any penalty by electricity board, so plz suggest me if i can permanantly install and switch on the 4 kvar capacitor or not at LV side of transformer just after energy meter? Thank you again and awaiting for ur positive reply soon.
9 12581Why converter duty transformer neutrals are not earthed...i am still not sure if this question is also correct...Please email at ranjan120482@gmail.com
2341How to decide the rating of CBCT? We have 6.6Kv switchgear & having 50/1 cbct ,i want to know how this 50/1 A came? On what basis we decide CBCT reting?
1 8771What is difference between Step Up Transformer & Booster Transformer? can we used instead of any one?
CS,
2 17584Difference Between Differential Relay and Restricted Earth Fault Relay of Power Transformers
KSEB,
1 11463
For 1 bag cement how i will calculate sand and metal aggregate;Here the mix proportion is 1:2.49:2.38
Define phase lag and phase lead?
Why air is not used to run the turbine?
HOW TO CHECK THE VECTOR GROUP OF A TRANSFORMER YD11?
What applicable rate of wct in bihar
How DC earth leakage currents can be reduced ?
What is called limb of a transformer?
what is stper motor
Can you explain the role of a production engineer in a manufacturing environment and the key responsibilities they typically handle?
how to change measuring units from mmwc to cubm/h in rosemount air flow transmitter with hart communicator fluke 744
hai, kindly send anyone for output workers format details for construction project in foundation to finishing.
Explain the application of using buck boost converter.
Explain why diesel engine is known as high torque and petrol engine as high speed engine?
What is the strength of 1:6:12 mix?
Thermal withstand capability under full short circuit conditions, in terms of number of times of occurrence of short circuit and corresponding anticipated percentage reduction in transformer life.