Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379) An engine operates between temperatures of 900 K and T2. And another engine between T2 and 400 K. For both to do equal work, the value of T2 should be
BITS,
3 7336Wasco Interview 1-the type of transducer that convert mechanical movement into a voltage 2-pump 2500 psi and 100 MG select it 3-modes of heat transfer 4-the difference bet PSIA and PSIG 5-the function of relief valve and no return valve (check valve ) 6-types of bearing general catogires 7-function of bearing 8-compressor surge 9-pump cavitation 10-define critical speed 11-compression ratio decease volumetric ratio ........... 12-using inter-cooling in multi stage compressors to ....... 13-using cascade system in refrigerator function ? 14-define performance and efficiency .
2034what are the various login options used in loadrunner tool to make a application performance testing
1883
Explain the purpose of the package around a microprocessor silicon die?
How to calculate VA rating for CT or PT or Control Transformer?
How much inductance or resistance require as a starter in series with induction motor of specific capacity(e.g. 5 hp) ? What is formula for it ?
plz send jto previous papers
interviw tips for bhel supervisor trainee
15hp motor wound by 0.9mm & 0.95mm magnet wire. at no load test it draw 4.2A current. Another motor with same condition draw 9.2A current. How can that occur? pls help
3Cx240 & 3Cx300 sqmm Al. cable from lv side. What is the calculation for this cable??
We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks
What is the common source of leak in stern tube
distance between the power generation and the distribution to the application is fixed or vary
how to increase or decrease speed in DC shunt motor by DC convertor
Explain we take the area of collector wide comparison to base and emitter. Why?
Explain various types of breaks.
what are symmetrical and non symmetrical components in electrical installation.
What is Primary And Secondary Injection Test of Relay and Other Electrical Devices. How IT is carried out.