Engineering Interview Questions
Questions Answers Views Company eMail

give the full form for upvc pipe & cpvc pipe

ME, PVC, SWR,

4 74990

what is the proper location of sample point for sphere tank?

1565

IS THE SAMPLE POINT OF LPG SPHERE TANK PEFOR OR AFTER BUMP?

1609

WHAT IS THE PROPER LOCATION OF SAMPLE POINT OF LPG SPHERE TANK?

1967

what type of motor is used in washing machine

8 32459

If a 3 phase transformer is a 500 kva using the formulae 500kva= 500000/433 x 1.732 = 666.71amps does this mean that each phase on the secondary side is 666.71

Saffron,

3 9800

why all selected supply voltages are multiple of 11.i.e440,11 kv,33 kv,66 kv,110 kv etc

Suzlon, TCS,

6 12215

when an induction motor runs on load.at that time if we reduce the supply voltage the current increases.But when it runs without load,if we reduce the supply voltage the current also reduced.why?.i checked it practically also.

Birla,

1 3357

What is mean by power factor?

1 3295

I have two AC generators, the first rated 2680KVA for 380V/4345A/pf:0.7 and the second rated 3461KVA for 5500V/363A/pf:0.8. I want to parallel the two generator to a bus. The second generator passes through a transformer to down the voltage to 380V and a part of its power goes to another bus so that it's only a part of the total power of the second generator taht goes to the considered bus. I have two Basler DECS100 AVR regulator. How can I make the synchronization ? What others equipments must have ?

CST,

1 2074

What is the basis of choice for cement sand plaster in ratio 1:4 and 1:6 on interior walls of a residential apartment.

Gammon,

3 18794

i am Ali from Hyderabad,having twice rejected on conference visa(USA),possessing 9 years of teaching experience,my current ielts score is 6 bands and my current age is 34,do suggest me some suitable universities for MBA course in USA,and what are the prospect of getting a visa.

1505

how does refractive index detector work?

2255

plz plz help me "how can i face dell varcent round"....? plzzzzzzzz help me friends.....?

DELL,

1558

What is EARTH COUPLING. Have come across,a pnuematic index table Machine is vertical drilling machine made by Chiron GMBH

1713


Un-Answered Questions { Engineering }

State assumptions made for analyzing ideal op-amp.

643


how much percent are used 20mm,10mm?

1455


What is the effect on Power factor and capacitor when your company load is more than 70 % of welding transformer

1352


specify the inbuilt protections in DG

1628


Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?

1535






what is a composite error in current transformers, why occurs & in which it will occur i.e, either metering ct/ protection ct

1304


What are the major disadvantages of product grouping?

562


Define what kind of cleaning substance or treatments keep or help prevent cast iron from rusting?

545


Where is servomechanism used?

667


give comparison of three wire & two wire sensors.

1594


when the generator running trip by earth current even though engine all so shut down the problem showing gcs waring and emergency trip there after starting always gcs locked out what is the problem [this is cummins qsk 23 electronic controle module governer

1346


Define thermal resistance in the context of power amplifier.

614


what kinds of Transformer oil grade is better for power transformer ?

1185


What is the cut-off rate?

726


sir, what is the importance of Fault MVA. how to calculate fault mva of 33kv substation connected by 6.5 km line(single circuit with equal spacing) with 110/11kv transformer in 110kv susbstation.the fault mva on 11 kv bus in 110kv susbstation is 208mva.

2495