Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


How to check hplc detecter sensitivity?



How to check hplc detecter sensitivity?..

Answer / babasaheb gilbile

In Waters HPLC 1 ml flow for methanol passing with wavelenth 230nm. and after 1hr check the Detector lamda max value. If ie greater than 20 the detector sensitivity is good

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

importance of internal standard and in what conditions it is used?

1 Answers  


Why potassium dichromate is used in calibration of uv?

0 Answers  


Column selection in HPLC method development?

1 Answers  


Why we use buffers Acetate for pH 4.5 & phosphate for 6.8 and not vice-versa?

1 Answers   Zydus Cadila,


why we multiply 1000 in the determination of kf factor ?

3 Answers   Stellence Pharm Science,


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5&#61620; 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

0 Answers  


perchloric acid&glacal acetic acid both are acids but reaction is complete in volumetric titrations.how?

1 Answers  


How to calculate coreletion coefficient

0 Answers  


Sulphated Ash incresed it will effect on product yield?

3 Answers   Biocon, Lupin,


We use Potassium Dichromate solution for the calibration of UV-Visible Spectrophotometer in UV region. My question is to calibrate visible region which solution could be used in photometric accuracy

0 Answers  


Is sonication essential in solubility testing of a drug substance?

6 Answers   Aurobindo,


Colorimtry

0 Answers   Dr Reddys,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)