Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Data was integrated with RRT CONCEPT OR Overlay with SSTchrmatogram concept which is better?



Data was integrated with RRT CONCEPT OR Overlay with SSTchrmatogram concept which is better?..

Answer / pranal

If impurity injected then compare the sample with sst solution and if not injected the impurity then use RRT to identify peak

Is This Answer Correct ?    2 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

What is descriminatory disolution medium ?

3 Answers   Cipla, Graviti Pharmaceuticals,


What is the difference of time between two consecutive injections in HPLC?

2 Answers   Nectar Lifesciences,


what is a placebo peak

2 Answers   GMP Pharma, Optimus,


significane of detector wavelength accrucy in calibration of hplc

1 Answers  


Principle of single pan analytical balance

0 Answers   Amneal Pharmaceuticals, Bayer, Dr Reddys,


Why sulfuric acid is used in sulphated ash / residue on ignition test.

9 Answers   CS Pharmaceuticals, Dr Reddys, GVK, HPLC, Micro Labs, Samrudh, Watson Pharmaceuticals, Wings Customer Care,


why the same column give different retention time in hplc?

7 Answers  


in determination of(acetone) moister content we are using methanol replaced by pyredine.what hapend in that reaction.

2 Answers   Glenmark, Neuland,


how to calculate elemental impurities?

0 Answers  


Why we use Caffeine in hplc calibration

2 Answers   Emcure, Laurus,


Why dst is used in kf for factor determination less than 1

4 Answers   Reddy Labs, Sun Pharma,


acceptance criteria for ph meter, hplc detector,pump,injector,oven when we calibrate.

3 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)