Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


U have 4 strengths have different coating meterial which one u chose to do forced degradation stady in validation



U have 4 strengths have different coating meterial which one u chose to do forced degradation stady ..

Answer / tushar chavda

check the ratio of excipient in all strength and whcich strength contains high ratio of excipient we can use for FD study

Is This Answer Correct ?    4 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

What is the principle of Thermal conductivity detector and FID?

0 Answers   Cipla,


why using factor 1.00639 in burette calibration of kf

1 Answers   Cipla,


which are the diffrent batches in the pharmaceuticals?

0 Answers  


how to start the method development of Dissolution and related substances.

1 Answers   Apex,


please explain about aluminium hydroxide assay

0 Answers  


key components in hplc?

3 Answers   Laurus,


what is the difference between heavy metals and sulphated ash

2 Answers   Aurobindo,


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

0 Answers  


what is dwell volume in HPLC?

2 Answers   Aurobindo, Cadila, Strides, SUN, Sun Pharma,


why we use TLC?

8 Answers  


How to calibrate glassware against std calibrated glassware?

3 Answers   Cadila, Hetero,


How decided 10 ppm standard solution in Swab, rinse method.?

2 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)