Why  we are always  only used 11 kv.  , 22 kv ,33kv      in transmission line? Why not use 25,  55 ,65 kv ?

Answers were Sorted based on User's Feedback



Why  we are always  only used 11 kv.  , 22 kv ,33kv      in transmissi..

Answer / ukumar

rms/form factor=1.1 its multification factor of transmission so its calculate 11,33,66....

Is This Answer Correct ?    10 Yes 2 No

Why  we are always  only used 11 kv.  , 22 kv ,33kv      in transmissi..

Answer / achal

It has no answer. People say and link it to some equations but for real it has been chosen randomly and now it has became an standard.

Is This Answer Correct ?    3 Yes 3 No

Why  we are always  only used 11 kv.  , 22 kv ,33kv      in transmissi..

Answer / engr ahmad

our teachers in University has also said like this that actually this is 13 kv generated and not 11....so i think its not necessarily 11. it could be any...

Is This Answer Correct ?    1 Yes 1 No

Post New Answer

More Electrical Engineering Interview Questions

how "rabbit ACSR" conductors are more efficient than "weasel ACSR" conductors

1 Answers   AITM,


How can i get my certificate of competency as an electrical supervisor? I have complicated my B.Tech from Uttarakhand technical university this year (2012).

1 Answers   ONGC,


30 kva ups may kitne output voltage hote h

1 Answers   ME,


why we are using the 2 slope in differential relay?but in busbar differential we are using only one slope. what is the reason.

1 Answers  


wat will be the pressure maintained inside the transformer?

2 Answers  


What is difference b/w Microwave and OPGW ??

1 Answers  


I have 150/1A Rating CT Suppose if i inject 15A in CT " Secondary" means what will happen ??????

1 Answers  


sir, how to select the cable size, what is the parameters use ang what is the formulas use for this cable size calculations. please tell me.

4 Answers   ISRO, Power Grid,


what s a servo motor? how to control the servo motor? and its application, purpose of using?

2 Answers   Arabian Pipes,


why alternator is used instead of dc generator and induction generator

1 Answers  


A 10 MVA, 66KV, 50Hz, Y-connected 3-phase alternator has synchronous reactance of 0.635 Ù. It is working at full load at 0.8 lagging p.f. condition. Find torque angle, neglect armature resistance.

1 Answers   VECL,


what is the location of lighting switch of battery room

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)