Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


In Agilent HPLC calibration using Empower 3 Software, What is the criteria for GPV Baseline starting point? i.e., Either it can start from -0.00/+0.00 or any range is there like -0.05 to +0.05 or ......etc?



In Agilent HPLC calibration using Empower 3 Software, What is the criteria for GPV Baseline starting..

Answer / obaiahkade

Primary verification test k2 cr2 o7 holmiam perchloride are used

Is This Answer Correct ?    0 Yes 3 No

Post New Answer

More Analytical Chemistry Interview Questions

In UV-VIS spectrophotometer:My diluent is methanol even though i corrected base line for methanol,In my sample scan i found methanol peak.what is the reason?

2 Answers  


Why we have to use KBr pellet technology ?

1 Answers  


What is cleaning validation of rinse and swabe and its limit with caculation formula.

5 Answers  


mahagenco syllabus for the post of chemist

0 Answers   MahaGenco, Unimarck Pharma,


what are the normalisation, internal standard and external standerd methods in HPLC.

2 Answers   GVK,


same sample on two preapration gives differnt result during hplc analysis

3 Answers  


I have got selected for Aurobindo Pharma AR&D, HR person is asking me to sign in agreement. can I join?

19 Answers   Aurobindo,


From peak purity spectrum, where or at which point peak purity angle & purity threshold is checked?

1 Answers   Cipla, MSN Pharma,


How we can determine OOT limit in Stability

2 Answers   MSN Pharma,


what is the diference between spectroscopy and chromatography

2 Answers   Cipla, PharmChem, Reliance,


Why six unit used for precision?

0 Answers  


analytical method validation require to with respect to release specification or shelf life specification?

0 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)