how much difference we have to provide when column steel staggered

Answers were Sorted based on User's Feedback



how much difference we have to provide when column steel staggered..

Answer / mehul kothari

Lap should be staggered min 1m
But if it is not possible on site condition or you are not able to stood column vertically lap can be provided in between h/4 from top and bottom

If i use easy word to explain you can leave staggerd in middle of column

H/4 should be calculated as clear hight of column

Means h= heiht of slab - thickness of slab - depth of beam

Is This Answer Correct ?    0 Yes 0 No

how much difference we have to provide when column steel staggered..

Answer / shashi roy

.3l

Is This Answer Correct ?    0 Yes 6 No

how much difference we have to provide when column steel staggered..

Answer / sjtbehera

±5mm

Is This Answer Correct ?    0 Yes 6 No

Post New Answer

More Civil Engineering Interview Questions

How much paint is required for 1sqm.?how to calculate the paint...?

1 Answers   MRKR, Sumadhura Infracon,


how much water you will add to the mix, for making 1 m3 of concrete to achieve strength of mix 20N/mm2 at 28 days.

11 Answers  


External staircase area outside the independant house includes in plinth area or not?

1 Answers  


how to calculate the dry wt of sand and cement for a required design mix?for ex:M20

0 Answers   Bhugan Infracon, UltraTech,


"Why you consider yourself suitable for the post"

17 Answers   Banking, CSE, IIP, IREDA, L&T, Maytas, McHugh, Nations Trust Bank, Teaching, Techkriti IIT Kanpur, Xantium Integrated Solutions,






what is difference between long column and short column?

16 Answers   L&T, Tomi Polytechnic,


what is 20 mm dia equivalent reinforcement in column with 25 mm dia 3nos and 32 mm dia 3 nos?

1 Answers  


what"s the formula for circumference?

12 Answers   Ashok Leyland,


how to calculate the rebar depth if forgot the foundation reinforcement (main steel)? is that any calculation or formula we have data sheet of supplier what depth what is the pull out capacity is mensioned in data sheet. if any IS code than its help full to me.

0 Answers  


why the profile of shell of natural draught cooling tower is hyperabolic.

0 Answers  


how to find number of 16mm bar reqired for 5m length with 125 mm spacing ?

6 Answers  


how to calculate width and thickness of columns and beams for differnt area with example

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5084)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)