Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


what can saybolt viscometer do?



what can saybolt viscometer do?..

Answer / goldpan

Purpose:

The instrument is designed and made as per T0623 “Asphalt
Saybolt Viscosity Test (Saybolt Viscometer Methods)” in the
Industry Standard JTJ052 Specification and Test Methods of
Bitumen and Bituminous Mixture for Highway Engineering. It
is used to determine viscosity of petroleum asphalt and
liquid petroleum asphalt. It is used to decide the
construction temperature.

Main structure and characteristics
The instrument is mainly composed of bath, bath temperature
controller, and measurement parameters display calculator
(calibration coefficient, time, viscosity, etc).
The instrument adopts microprocessor controlling technology
and has function of two-way determination. It can make
parallel determination for two samples at the same time. It
can digitally show test parameters and calculate average
value of test data. It can also convert Saybolt viscosity
into Engler viscosity or Kinematic viscosity. Only make
determination once, you can get three types of test data.
It is efficient and reliable.

Technical parameters
1. Power supply: AC 220V±10%, 50 Hz;
2. Types: Desktop;
3. Working mode: Two-way determination; parallel test;
4. Sample receiving bottle: 60±0.05ml;
5. Heating power: 1000 W;
6. Working temperature range of bath: room temperature
&#8764;240.0°C;
7. Temperature controlling accuracy of bath: ±0.1°C;
8. Timing range: 0.0s&#8764;999.9s;
9. Timing accuracy: ±0.1s;
10. Ambient temperature: &#8804;35°C;
11. Relative humidity: &#8804;85%

Is This Answer Correct ?    7 Yes 1 No

Post New Answer

More Physical Chemistry Interview Questions

2day science says that clouds r formed due to sea(more than 90% sea water in cloud). but when rain starts,,,,the rainy water is sweet while sea (salty)water is salty.....how sea water is converted into sweet water?

1 Answers  


In testing of Cement the formula for water requirement for setting time is as below- Water required for setting time = NC x 0.85 The question is that what is the logic of 0.85 in this formula??

0 Answers   Grasim,


What is unsaponifiable matters?

1 Answers  


what does 50 denote in dowex 50 ????

0 Answers  


what kind of question can be asked in interview for UV- VISIBLE & give me answer ?

0 Answers  


what is an Amphipathic protein?

3 Answers  


Balance the following redox equations by ion electron method. In basic medium (i) CN- + MnO4- CNO- + MnO2 In Acidic medium (ii) ClO3- + Cl- Cl2 + ClO2

1 Answers   Chemical, Wipro,


How much is the molar extinction coefficient of methylene blue at wavelenght 664 nm? Are molar extinction coefficient depend on concentration of solution?

3 Answers   Indfrag Limited,


why silica absorb in mix bed resins in D M plant.

8 Answers   NTPC,


who is minister of railoway

1 Answers   HKL,


how many types of stability in pharma or API industry ?

2 Answers   Unimarck Pharma,


How to accelerate electron capture decay?

0 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)