in transmission line, if the load is suddenly increased at
the receiving end of the system the phase shift will
(a)decrease
(b)becomems zero
(c)increase
(d)not be affected

Answers were Sorted based on User's Feedback



in transmission line, if the load is suddenly increased at the receiving end of the system the pha..

Answer / ketan

increase

Is This Answer Correct ?    3 Yes 0 No

in transmission line, if the load is suddenly increased at the receiving end of the system the pha..

Answer / bhargav

C) increase

Is This Answer Correct ?    2 Yes 0 No

in transmission line, if the load is suddenly increased at the receiving end of the system the pha..

Answer / sagar kumar

I don't know this answer. I post answer only to receive correct answer.

Is This Answer Correct ?    1 Yes 0 No

in transmission line, if the load is suddenly increased at the receiving end of the system the pha..

Answer / anbarasan j

Not be affected

Is This Answer Correct ?    2 Yes 3 No

Post New Answer

More Electrical Engineering Interview Questions

what will be the effect on the voltage .if power frequency is increasing or decreasing.

2 Answers  


Why we use circular(Stepped) cross section in transformer core?

0 Answers  


where is highest transmission voltage is used in india

2 Answers  


a transformer can have zero voltage regulation a)o pf b)1 pf c)lagg pf d)lead pf

2 Answers   SJVN,


can anibody tel me on what basis the transformer vector groups are determined????

1 Answers  






I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.

2 Answers  


what is the electricity

3 Answers  


In a Dyn11 transformer, how are the 3 windings of the delta connected? Assume that R1-R2, Y1-Y2, B1-B2 are the 3 windings on the HV side.

3 Answers  


hi pot test principal

1 Answers   NTPC,


how you connect the induction motor first in star and then delta in star-delta starter

1 Answers  


hey guys i recently saw a long transmission line in which a sort of balloons in red and white color were hanging at each section.do u have any idea why are they kept for?

3 Answers  


Hot Water System (HWS). Will a 30ma elcb have more nuisance tripping than 100ma elcb

1 Answers   CIMC,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4452)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)