Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why we are using K2Cr2O7 for control of absorbance in UV?

Answers were Sorted based on User's Feedback



Why we are using K2Cr2O7 for control of absorbance in UV?..

Answer / smitadeb86

Control of absorbance is verified using known amount of Potassium dichromate solution and checking the absorbances at various wavelengths, to establish that the resulting E ( 1% 1 cm) levels at those wavelengths, are within the permitted tolerances.

Is This Answer Correct ?    8 Yes 0 No

Why we are using K2Cr2O7 for control of absorbance in UV?..

Answer / d.lodhiya

Because its having 2 peak and 2 vallay . stable and
standard upto 3 hrs. its obays bees law.(ABS .25 to 1A)

Is This Answer Correct ?    9 Yes 3 No

Post New Answer

More Analytical Chemistry Interview Questions

Why dissolution test apparatus calibration with salycilic acid tablets was stopped by FDA&USP from the year of 2009?

1 Answers   Aurobindo,


for heavy metal test lead used in which form pure form or any other form for preparation of lead standard sol

1 Answers   Watson Pharmaceuticals,


why in hplc peaks are in positive side(it means upside) not in negative side?

3 Answers  


What is the size of capillary tube used for analysing melting point?

1 Answers   Apotex,


in calibration of disintegration test apparatus why cycle limit is 28-32?

2 Answers   Caplin Point,


why we use pyridine to determine moisture content of acetonel

2 Answers   Lee Pharma,


in DMF having extra impurities and in api COA also having extra imp than USP or BP product then how require to proceed?

0 Answers  


why we use prednisone tablet in chemical callibration of dissolution apparatus?

6 Answers   Cipla, Mylan, Umedica Laboratories,


acetic acid is weak acid & perchloric acid is strong acid.but how perchloric acid is soluble in acetic acid

3 Answers   AVT, Hetero,


k.f principle in finding out moisture content

1 Answers  


What is void volume & dead volueme

3 Answers   Bayer, Lupin,


why we can use only 4 and 7 and 9 buffers in pH calibration

1 Answers   Chola, Cipla,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)