Why Methanol used in KF Titration?

Answers were Sorted based on User's Feedback



Why Methanol used in KF Titration?..

Answer / dhiraj tiwari

Methanol is polar solvent.all drug are also polar nature and neutralized the kf reagent.

Is This Answer Correct ?    1 Yes 0 No

Why Methanol used in KF Titration?..

Answer / samba shiva reddy.p

methanol prevent to rxn betwen pyridine and so2,methanol also primary alchol nd all sample eaisly disloev in dis soovent

Is This Answer Correct ?    1 Yes 0 No

Why Methanol used in KF Titration?..

Answer / y srinivasarao

All drugs are polar nature thats y using methanol

Is This Answer Correct ?    0 Yes 0 No

Why Methanol used in KF Titration?..

Answer / madhukar tayade

Because the methanol is easily available solvent,readily mix with other compound,maintain the pH that is required for the reaction to be carried out without side reaction

Is This Answer Correct ?    8 Yes 11 No

Why Methanol used in KF Titration?..

Answer / saikiran

when compared the other solvents methanol having low
quantity of water content and use dry methanol widley. in
KF test to find out the water content in given sample so
we use low water content solvent.

Is This Answer Correct ?    9 Yes 16 No

Post New Answer

More Analytical Chemistry Interview Questions

in HPLC injection volume is increase ,R.T will increase ?

5 Answers   Claris Lifesciences,


when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.

1 Answers   ABC,


Why we use buffers Acetate for pH 4.5 & phosphate for 6.8 and not vice-versa?

1 Answers   Zydus Cadila,


why we get negative values in uv when i placed sample which has some concetration but not in standard

1 Answers   Nirma,


is ther any guidline is available for limt of peak fronting.and what is the limt of peak fronting.

2 Answers  


If we are getting split peak in Chromatogram,what we can do?

7 Answers  


wt is rsd in and explain

4 Answers   Cadila, Reddy Labs,


In dissolution test s1 stage we are getting one bowl 40 % out of 6 bowls what is the root cause you find and how proceed next step? ( Q is 80%)

3 Answers   Reddy Labs,


what type of question will ask in the interview of lab chemist.

1 Answers   Godavari Biorefineries, Monginis,


which situation gc hs and gc als require to use?

1 Answers  


When you get Moisture content by KF higher than by LOD, what does this indicate?

7 Answers  


loss on drying we applied vaccum for some compounds and some compounds are at 105c why

3 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)