why can't you use centrifugal pumps for pumping viscous fluids?

Answers were Sorted based on User's Feedback



why can't you use centrifugal pumps for pumping viscous fluids?..

Answer / chaitanya pithawa

because in centrifugal pump,if the density of the fluid is
higher means viscous fluid,the power consumed is very much
higher and there will be a chance of changing the shape of
the impeller or it may bend.
centrifugal pump rotates very fast and so it wont easily
pump viscous material because higher viscosity of fluid
which increases the friction with the blading.
viscous material need thrust or force to push ahead,so for
that it is more convenient not to use centrifugal pump.

Is This Answer Correct ?    11 Yes 1 No

why can't you use centrifugal pumps for pumping viscous fluids?..

Answer / saurabh malviya

u r ryt , chaitanya sir .....obviously , a highly viscous fluid needs a greater force to overcome the shear force and to move along it requires thrust rather than a centrifugal action ........moreover , highly viscous fluid may cause impeller blades to bend by sticking to its surface .....screw pumps are generally employed for pumping highly viscous fluids...correct me if i m wrong anywhere.....

Is This Answer Correct ?    2 Yes 0 No

why can't you use centrifugal pumps for pumping viscous fluids?..

Answer / writick

gear pump is also good for viscous fluids

Is This Answer Correct ?    1 Yes 0 No

Post New Answer

More Mechanical Engineering Interview Questions

What is function of steam strainer?

2 Answers  


Explain the mechanical advantage of a double pulley?

1 Answers  


How do concrete pumps work?

1 Answers  


why diesel engine does not have spark plug like petrol engine, how ever petrol is better fuel than diesel?

16 Answers   HMT,


functions of machine?

1 Answers  


WHAT IS THE TOTAL HEAT RATE OF PLANT AND WHAT IS THE HEAT RATE OF BOILER?

1 Answers  


what is cavitation ?

13 Answers   Idea, IGCAR,


The shear modulus of most materials with respect to modulus of elasticity is less than half why?

1 Answers   DRDO, RVNL,


normally..what is the kilowatt for 1, 1.5, 2 ton split air conditioners

2 Answers  


i am studying in bechanical engineering in M,S,University at Baroda.i and my friends want to take one month industrial trainning in mechanical engineering company.pleas send some company's name and procedure.

1 Answers  


tell about Automobile engineering

2 Answers  


how to prepare welding procedure specification and pqr

1 Answers   Asmacs, JSIW Infrastructure,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)