Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

dielectric strength of vacuum is greater than SF6 but for 132Kv uses sf6 breaker & for 33kV uses vaccum breaker why such a contradiction?

MSETCL Maharashtra State Electricity Transmission Co Ltd,

2 4692

I have lowered a submersible pump having 100 LPM discharge & 130 Mts. Head, 15 HP rating on borewell. After lowering 108 Meters, It is taking 39 amps & blowing the fuse. Can someone put light what is the cause behind it ?

1 2306

I AM COMPLETED DIPLOMA IN E.E.E. AS WELL AS B.TECH IN ANDHARPRADESH.. HOW I THE Certificate of competency as Electrical Supervisor.

1 3121

What is the difference between acs 550 & acs 850

Madhucon,

5752

How to find ampere on ht side for selection of cable size ???

1753

1.Why sinle phase motor is not self starting 2.working principle of alternator 4.list out electrical formula

2 4048

What is the capacitance values of 132,220,400 & 765 kV current transformer

1869

Sir,I have finished my B.E in the Stream of EEE.How Can I get C license for Electrical???Please Tell me the way...My mail ID is praba1003105@gmail.com Cell:7402474123

1 2563

Please let me know when replacing electromechanical Relays for protection of generators with sr489 multilin Relay, then there is no need to use 86 master trip relay Too. I am wondering this multilin relay has no contact to Stop breaker reclosing as 86 does

Neucel,

1 2669

How do I calculate/select Droop CT ratio for various capacity of generators?

3607

What is power factor?

L&T,

3 7756

how is the incoming cable size calculated for a given current rating of a panel??

1875

what's the different between ELCB, ELR and ELS?

CP,

1 39389

how freewheeling diode improves the powerfactor

5365

What is minimum permicible value of leackage current for LT Panle when applying voltage up to 3 KV for 5 Minuits?

BFL,

2189


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

What is the difference between multimeter

1904


How to decide DO set rating of Transformer?

1614


how to carried out DAR test in 11 KV Alternator ?

2255


To prove the capacity of a 10MVA transforemr with 6.5% impedance by a short circuit test how much power is needed to inject an impedance voltage if we have to arrive for its rated current?

1863


how can we select the appropriate VCB ?

2248


what is your aim

1864


Name of the relay of low lub oil presuure in DG sets

1998


For a three phase induction motor, what will be the effect on motor if the neutral of the system is shifted to say 20 deg.?

1779


What is proportional controller?

1237


what is transient voltage?

2206


what does vector group Dyn11 tell us? also tell me how will u differentiate between phase lead and phase lag thru this vector group

2033


Following test should be conducted to find out relative polarity of transformenr terminals A no load test B back to back test C phasing out test D none of above

2171


is it possible to test of bus bar in high rise building without completed full floor ?

1633


TRAFO 1. WHY BREATHER IS USED. 2. WHY OIL GOES DOWN IN CONSERVATOR TANK. 3. WHY WE ARE TAKING OIL SAMPLE TAKING FROM BOTTOM OF TRANSFORMER. 4. HOW TO CHECK IR VALUE OF TRANSFORMER. 5. WHY OLTC HAVING BUCHHOLZ TRIP ONLY; WHY NO ALARM. 6. OFF LOAD TAP CHANGER OPERATION PROCEDURE. 7. TR. SHUTDOWN / ISOLATION PROCEDURE. 8. WHEN THREE TRS. IN PARALLEL, ONE TR. IS NOT SHARING THE LOAD – WHAT IS REASON AND WHAT YOU WILL DO. 9. WHY TR. HAS OLTC IN HV SIDE. 10. WHAT IS % IMPEDANCE. 11. WHY TR. RATING IN MVA. 12. WHAT IS VECTOR GROUP IN TR. 13. CONDITION FOR PARALLEL OPERATION OF TRS. 14. WHAT IS TERTIARY WINDING. WHERE IT WILL BE. 15. IF TR. TRIP ON BUCHHOLZ OR TAP CHANGER RELAY, WHAT YOU WILL DO. 16. DIFFERENCE BETWEEN OIL TEMP. AND WINDING TEMP. PROTECTION 17. HOW WINDING TEMP. IS MEASURED IN CAST RESIN TR. 18. DIFFERENT TYPES OF FAULTS IN TR. Trafo - Page-1 of 2 19. WHAT HAPPENS WHEN TR. CHARGED FROM LV. 20. WHAT WILL YOU DO IF MEGGER READING SHOWS ZERO BETWEEN LV WINDING AND EARTH. 21. CAN WE INTERCHANGE BUCHHOLZ RELAY OF MAIN TANK AND OLTC TANK. 22. IF THE LINE BETWEEN BREATHER AND CONSERVATOR TANK 23. LOCKED, WHAT WILL HAPPEN DURING LOAD CYCLE. 24. WHAT IS THE FUNCTION OF OIL SEAL IN BREATHER. 25. WHAT ARE LOCATIONS FOR BUCHHOLZ RELAY FIXED IN POWER TR. 26. WHAT ARE CHECKS IN POWER TR. DURING MAINTENANCE. 27. WHAT IS IMPORTANT WHEN WE CHECK OLTC OPERATION DURING MAINTENANCE. Trafo - Page 2 of 2

2355


where the lexical paramater will use in fron end?

1823