How to select, design,size & calculate for 11 KV/33KV/66KV/132KV/220 KV/440 KV circuit breaker for HT side of transformer protection/HT distribution protection?
2758in control scheme dc logic wiring commonly using negative loop,what is the reason?if we use positive looping what will happen?
2341Please give me a solid reason there are 2 ELCB's If we take Phase from ELCB NO:1 an Netural from ELCB N:2 why ELCB is tripping when we connect the Load?please brief me with detail
3 5121Can any body describe me why a soft starter is used for 6.6kv induction motor instead of VFD ?
1 4191Hi.. I am a BE GRaduate in E&E. I have 8.5 Experience in Tendering & Estimation field. I have done SAP SD course few years back. But due to some reason i failed to get job in that field and continued my own field. Now I am thinking of changing into SAP seriously. How should i go ahead???
1952draw a dol with the following rtds,stop/start,ct,vt and o/l supply is 6.6kv and the coil is 110v
1 4486Post New Electrical Engineering Questions
hello!my name is sheikh iam preparing for indian engineering servieces,please send me the old question papers..to sheikhshaazforjobs@gmail.com
What is the effect on power factor, shown by a trivector meter; incase of reverse phase sequence. If the power factor of a system is lag what meter will show in case of reverse phase sequence connected to the meter. and What in case of lead.
What are test signals and their significance?
Why air circuit breaker off due to power failure?
State angle criterion.
I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?
What is the difference between type1 and type2 relay protection co-ordination for motor feeders
what is the advantage of connecting capacitors in delta than in star?
What is the distance between body earthing and neutral earthing.?
WHAT IS DOL STARTER? HOW IT WORK? GIVE ITS CONTROL AND POWER DIAGRAM .
why zero sequence impedance measurement is not applicable for single phase GT
Why L.T.Cable voltage rating is 1.1kV,where as system voltage is 0.415kV?
What is the meaning of C1, C61, C91 cable
what is kondo syatem in eletrical traction
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.