Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

how will we calculate the copper wire load..

1933

Which of the following alternatives will be cheaper (1) A 100 h.p AC, 3-phase motor (2) Four motors of 25 h.p each (3) Five motors of 20 h.p each (4) 10 motors of 10 h.p each explain

3030

A synchronous machines has higher capacity for (1) Leading power factor (2) Lagging power factor (3) Does not depend upon the power factor of machine (4) None of the above

JSW,

2 16481

One 200 V, 100 W bulb is connected in series with primary of a 200 V, 10 kVA transformer. If its secondary is kept open circuited, then the bulb would have (1) Full brightness (2) Poor brightness (3) A little less than full brightness (4) More than full brightness...explain

2 9390

The maximum demand of consumer is 2 kW and his daily energy consumption is 20 units. Its Load Factor is (1) 10.15% (2) 41.6 % (3) 50 % (4) 60%

2 23842

what is the purpose of bypass mode in energy lighting transformer?

2486

what is meant by transformer differential protection ?

BFL,

3 5798

What happens if there is no nuetral in the power system?

5 7375

How to confirm the Phase shifting Transformer VECTOR GROUP relation , as below ZNy11.45d10.45-ZNYy0.15d11.15

3261

Can step down transformer works as step up one???

2 4526

what is submersible pump?what is different between motor and sub motor?

2060

We have ONLINE UPS 15KvA (3PHASE 440V I/P,3PHASE O/P,440V) I want to step down from 440 to 220 V What to do. Pl. suggest with specification.

ARDE,

1 3244

an ac induction motor gets overheated when operated at a low frequency of 25 hz a instead of 50 hz. reason?

1 3837

why synchronous motor is not self starting

Cenored,

5 7967

HOW TO CALCULATE S/C,O/C,E/F OF ACB.

2583


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

in power generator normaly voltagr betwween esth to neutral is 0 but my work place generator show the volatge is 60v any body know why? thanks

1900


What happen when neutral point connected to core balance current transformer? (Neutral point of an alternator of a 180KVA DG. Neutral point connected to CBCT means enter to the CBCT)

2286


What are your personal skills and abilities for such a Master Course and your possible preparation to undertake this course?

2044


Dear all i want to know SEWA Electrical Supervisor Licence test Previous Year Questions ? If any body know please send to me zohairaukllah@yahoo.com

1032


Following test should be conducted to find out relative polarity of transformenr terminals A no load test B back to back test C phasing out test D none of above

2216


How we can determine short circuiting current any plant and for example a plant which power generation is 415 volts and plant load is 500 kw.

1990


What is the difference between PS & metering CT (5p20,0.5 etc.)? Why in PS class CT only Vk is given ? Is PS class CT is more accurate than metering CT?

1123


As i want some model question paper in basic computer science and history please send me immediately sir

1883


what is the constructional difference between a power transformer and potentian transformer?

1758


do we use neutral grounding for resistive balanced load? if we use what happen?

1796


plz send me the placement interview question and answers of whizchip(technical and apttitude)..i have an interview in next.

4989


Why we use 4-20 mA Analog signal for the PLC input? Why not 0-20 mA? Why not 5-25 mA?

2903


what does mean of RCT and STR in diffrential CT?

4236


1600 KVA ka transformer hi aghar lt side par 800A aur voltage 420 ho to HT side ki cable ki rating keya ho gi?

2036


At what speed 1 HP motor can run an electric car of weighing 400 kg?

1583