Electrical Engineering Interview Questions
Questions Answers Views Company eMail

Hi My dear all Friends, There is a question regarding HVAC Engineering and widely used in Power Projects. Question- What is the diffrence Between REF, SEF and Differential Protection....???? Where REF - Restricted Earth Fault SEF - Senstive Earth Fault.

1711

Hi My Dear All Friends, There is one question it is widely used in Power Project's High Voltage Engineering. Question- What is the diffrence between Earth fault and Back up Earth Fault....???? . . . . . . Have A Good Day

1 3194

HOW BETTER VOLTAGE REGULATION IS OBTAINED BY HIGH VOLTAGE TRANSMISSION....?

Cummins,

1 3932

how to select battery for 15 KVA UPS with formula

2073

Disadventage of cable-gland earthing if any ?

1651

why dc series motor high speed motor

3 3815

how to calculate neutral current in three phase four wire system

Auto Meters,

1 3466

During Load testing of battery charger with temporary AC Generator .When reach 70% load Generator immediately shutdown .we could not able to Recognize ,what is exactly problem .Please kindly clarify us

1 2454

What should be the BDV value of a new transformer oil

3 6323

When we are working on transformer(132\11KV). we are going to isolate the transformer from both HV side and LV side. then we are applying grounding on both side. My question is that we required to isolate the VT which is still connected from secondary side.?

1 3024

i am iti student i have project to do. that IS 100MW 220\33KV SUBSTATION I WANT TO KNOW HOW TO START, LIKE CALCULATION, WHAT RATING OF CT,CVT, PT, ISOLATOR LIGHTING ARRESTER WAVE TRAP CIRCUIT BREAKER IN 22OKV SIDE, ALSO TO WARDS 33KV SIDE PLS HELP ME WITH THIS, THIS MY LIFE NOW, I KNOW AUTOCAD, I LIKE TO KNOW HOW TO CALCULATE ALL THE THINGS

3 4020

what's the activities of reactor in Buchholz relay?

Yahoo,

1 3763

CONSIDER A 415V/200V STEP DOWN TRANSFORMER.CAN WE USE USE IT AS STEP UP TRANSFORMER BY GIVING 200V IN SECONDARY AND TAKING OUTPUT FROM PRIMARY?

3 4278

Why starters are using the machines???

Alstom,

5 6741

What should be the magnetic balance test values for a 3 phase delta/star connected single primary dual secondary winding transformer (90 MVA / 2 X 45 MVA TRANSFORMER)

1405


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

give single line diagram of D.G distribution form alternator to main L.T panel?

7025


with help of neat sketch explain principle of TIG welding process

1445


i need to give section engineer (electrical engineer) for RRB. Please suggest some book

1445


why a tester wont shock while testing the power in house

1313


What do you mean by a phase angel of instrument transformer?

629






I want to merge a cable..in between two metering Cubicals which contains CT's and PT's and Energy meter..before taking merger..what are the common things required?

1118


What is the resonant peak?

630


how to select electronic timer(Star-Delta) setting for diff. rating motors

1449


how hydrogen cooled alternator undergo maintanence ? that is hydrogen when come in contact with air can result into explosions .

1507


How to select HT/MV cable size ?

1985


what is meaning of 230volts ac 50hzs ac supply is it rms or maximum to getting ac 230v what amount of max voltage they will send

1536


Phase control and integral control are used for?

1768


What is the difference between solid grounding and impedance grounding?

1531


how can we change the polarity of Alternating current rapidly? how frequency of ac can be controlled and changed easily?

1571


Mention the methods for starting an induction motor?

629