Electrical Engineering Interview Questions
Questions Answers Views Company eMail

what is the function of 1 phase preventer?

ABB, Electrical,

3 24689

How to calculate the slip ring induction motor rotor current and voltage.

Bhel,

1 23590

which sub is most horrible in four yr degree

2 3240

what's the requirement of Dy11d0 connection of 3 phase transformer?what's use of it?

Thermal Systems,

7359

We have studied about many techniques for finding the stability of system, ROOT LOCUS, ROUTH, BODE PLOT, POLER PLOT etc. In these which is used where. what are the difference among them... PLZ tell me.......

MSEB,

1660

What is the work of IGBT in ups?

2 8270

Why Ferranti effect is occoured in leading power factor load in a overhead transmission line?

1 4548

Why ferranti effect occurred in leading p.f load?

1 3112

What is VCC?

1 2136

why the transformer neutral give to the earth ?

Jindal, JLL,

2 3522

This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

1993

Why we are putting off the APFC(automatic power factor control) panel while the generator is running?

National Steel,

4 10122

WHICH TYPE OF TRANSFORMER IS USED IN POWER TRANSMISSION BASED ON TRANSFORMER CONNECTION ON PRIMARY AND SECONDARY SIDE

3 4512

Can We Apply DC POWER To Transformer???? And Why????

4 4971

how i caculate the cable size for power factor correction unit for example 300kvar

1 2774


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

Can anybody please refer the best and simple book for about Protection relays and in detail of all its protection ?

1473


why normally Generator rating are between 11Kv to 22Kv?

3697


In cable sizing calculation (determining the max route length of cable) why we choose the shortest length between cable length of full load current Iflc & starting current Istart?

2760


How 3 phase invertor works?

1486


Dear all i am kumaravel. now in chennai. my work is control and relay panel auto cad designing.up to 11kv to 400kv then question is i am improving my knowledge. i want some books name and auther are available for this C&R panel related. plese any one help me

1366






what is mean by transition resistance of transformer?

3949


What are the different towers used in 132kv transmission line? what are the differences between the P,R,S towers used in 132KV and detailed explanation

1424


What is boucholz relay and the significance of it in to the trformer?

646


hai...... tis is Hemanth. jst now completed electrical engineering... i wanna to apper for ap tranco exam... plzz send me the previous q's paper link......thanx in advance.

1573


What is resistance of 50meters, 16sq.mm, single core copper cable?

1433


During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP

1394


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1331


what is the calculation method to design core and winding of a 200kva 3phase distribution transformer?

1918


Explain about 3 phase motor fault current calculation with examples?

2400


how define the torque in ac drive. from electrical side in the drive friquency ,voltage and current three factor is there.

1613