What are the protection required for Transformer, motor, Line, Generator, capacitor, that all i have to refer which standard?(Like Transformer detail IS 2026)
1949what is the basic difference between synchronous motor,synchronous generator and induction motor
7 21810Which standard i will refer for size of earthing conductor for equipment? (Eg:415V Switchgear, MCC, DB shall be 50x6mm GI flat)
1 4987If the output of a 100kva, 415v generator is stepped up to 11kv with a 500kva transformer,can the transformer be Loaded above the source generator loading?
2 4302A powerplant has 8 gensets operating in grid parallel mode. In one genset sometimes there is pf variation and kvar variation. The plant operates in pf mode. When this variation is observed the load is stable, voltage is also stable, freq and genset speed is also stable. How will you check the functioning of pf card. What shall be the ideal output vdc of the pfc, from there it is input to AVR?
2280IF THE OUTPUT OF A 100KVA, 415V GENERATOR IS STEPPED UP TO 11KV WITH A 500KVA TRANSFORMER,CAN THE TRANSFORMER BE LOADED ABOVE THE SOURCE GENERATOR RATING?
4 9976Post New Electrical Engineering Questions
Inductor and capacitor........power in one phase and ...... in it another phase.
Use of switch mode power converter in real-time basis?
Define bibo stability.
what is the relation between size of the anteena and wavelenghth of radiated wave
in our all power plant have connected in grid and grid voltage and plant voltage is same, but as per as electrical concept the power will transmit from high potential to low potential but here altough same,then how power transmit from power plant to grid.
In DC generator, we use commutator, having no. of segments. Then how it is possible to get a half wave of voltage and current for half rotation of armature?
Can i replace Earth leakage relay to the faulty Earth Faulty Relay
i want to know how to determine that a surge arrester work properly in 11kv system. and how to test a 12kv surge arrester
How do we find the rating of a transformer, if it got burnt badly.
What are the types of power in electrical power?
Why neutral point is consider as zero potential?
Why there are some equipment(i.e:TV) that using 2-pin plug instead of three? What happen if there is current leakage? Are we going to get electric shock??
what is the difference between "Rotary bypass isolation switch and Normal bypass switch" pls share indepth techs?
How to select the proper VSD to operate high inertial load
state the disadvantages of carbon filament???