Will any motor burn if voltage provided is lesser than the rated voltage???? If yes, then how is speed control possible with voltage control
2215Why, the starting current of 3 phase Induction Motor is 7 to 8 times its rated current?
L&T,
9 37243Hi everyone. Some Generators uses 3-Pole breakers with extra contactors for Neutral. Some uses 4-Pole. Why so? What is the idea behind this? Thanks in advance for the solution. Kr.
21291.protection used in transformer ? 2.Why breather called breather ? 3.Working of conservator tank.? 4.Speaker of parliament ?
4 11404Why CTs are connected in star on T/F delta connected winding side & in delta on T/F star connected winding side for T/F differential protection?
2 5705how to calculate cable size, olr rating, contactor rating and mccb rating,to below given details three phase motor 75 kw,415 v,.85 pf,50 hz?
5 74250Post New Electrical Engineering Questions
11 kv input, 66 kv input advantages
How do we calculate transformer oil in liter from the rating of the transformer.
what will happen if OLR CT in all phases are short circuted
What is the kiosk parts, about them and their functions ? If anybody have some PDFs files or details about this plz send it on tawhidfaisal@Yahoo.com
why don't we use the generator as a motor? and what will happen?
what is LSR?
from which formula we select a capacitor rating?
state the disadvantages of carbon filament???
Good morning: I'm looking for some informations about the OLTC or the LTC: I wont to know what the function of the tie-resistor in during the operation of reversing/coarse operation Cordially
what is meant by impedance & transient protection?
What is referred to the electron in the outer orbit?
Why 3 phase induction motor getting supply in body if one of it's phase is cut
How can claculate to attain the desired PF in the line ( HOW Much KVAR is required ) Pls Give the formula? Equate Petrochemical 0 1 how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec. 0 1 What will happened. if we feed 3phase supplay to the stater with out insert the rotor. How much current will flow through the stater winnding? Equate Petrochemical 0 1 What is required of exietation to the alternater. 0 1 why star point of HT motor not earthed? Equate Petrochemical 0 1 Why we are getting low voltage in star connection? Equate Petrochemical 0 2 What's ND relay & it's functions? Equate Petrochemical 0 2 How instantanious short circuit current is calculated? its formula? Equate Petrochemical 0 2 What is servo Motor? What's the advantages of this motor over Induction motor? Equate Petrochemical 0 2 What is core CT & it's function? Equate Petrochemical 0 3 what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY L & T 0 4 What is required of exietation to the alternater. KNB 1 23 what is the design voltage for 6.6KV 2000 KVAR HT capacitor? Consultancy 0 3 Pls explain about vfd control?Where it is used, Give some example? siemens 1 22 Please explain me abt PQ diagaram in the power sector. 0 9
What are the advantages of thermal power plant?
why a tester wont shock while testing the power in house