why two fuses are used in battery charging room?one in positive line and the other in negative line?do any DC system require two fuses?
HPCL,
1 4535How u can give the overload setting to any motor protection relay for a HT motors with formula and Example?
OCL,
2192. How to calculate the Short Circuit Impedance in Transformer? How to calculate the Short Circuit Impedance in Transformer?
2156What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?
1995While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply
2 8701What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?
2010Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example?
2228Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient?
1 4297Post New Electrical Engineering Questions
1.What is captive power plant? 2.What is national grid?Give brief idea.
Is potential difference materials property ..? if yes tnen how.. explain brifly.
how can calculate resistance box for 15 kw, 6 pole, RV-230, RA-42 motor
Is it possible to measure the voltage of a battery from a single terminal?
How to size Air Circuit breaker (ACB)? What is the most important factors?
salam&hi, i need to know about how can i calculate an enough current for the new building before i submit it to the suppliers
How does PLC work for sychronising of Two or more DG sets?
In EB metering we face problem kva jump even in no load condition.can any one help to control this
Why do we avoid electrical conduits in floors at apartments?
Define bibo stability.
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
Why use the vcb at high transmission system ? Why can’t use acb?
is it possible to turn on the single phase star delta on delay timer using 24 v dc ?
how to modify DOL control panel into Delta Y connection?
Please clarify 1. Icw: rated short circuit working withstand capacity 2. Icu: Rated ultimate breaking capacity 3. Ics: Rated service short circut withstand capacity 4. other specification of ACB