how we calculate the motor rating of pump for water suction ?its any formula for that plz give thank u

3 7135

on what factor insulation resistance depends

Uttam Sugar,

2 8374

explain how to protect high rise building from the risk of lighting.

1 1766

State uses of different types of stsrters with different capacities of motors as below: a. up to 5HP b. above 5hp to 10hp c. above 10hp to 20hp d. above 20hp

1464

What is power factor? How to improve Power factor? draw a circuit diagram showing the connection of power factor improvement equipment to the electrical instillation.

1 2305

A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram

2365

what is load balancing. what maximum load diffence is allowed between phases.

1 3510

-What shall be short circuit current of LV switchgear for a 1000 kva, 11.415kv, 3 phase tranformer with 5% reactance.

1666

-How do you select cable size for a given load at a given distance from source of supply. How do you find voltage drop.

1351

-What should be minimum value of insulation resistance and maximum value of earth resistance at any electrical instillation and what is method of testing the same.

1563

-What is leakage current . how much leakage current is allowed.

3 10037

why fuse is not used in neutral...

12 31781

what is the relationship between horse power and watts

9 20211

what is power and what is watts detailed description and formulas

2 3678

why 30 ma elcb is used ?why cant 100 ma?

3 22485


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

How to minimize the eddy current losses?

629


While performing stability test of differintial cts how to know the voltage and current on both side of the transformer?

3051


EXPLAIN THE ESSENTIAL FACTORS WHICH INFLUENCES THE CHOICE OF SITE FOR A HYDRO ELECTRIC POWER PLANT

1546


What are the site acceptance tests for power cables, DG Sets, LT panels & 30kVA UPS ?

1889


what is the difference between electrical choke and electronic choke?

2082






I AM FROM ELECTRICAL ENGINEERING ? I AM ASPIRING FOR "BHEL".HOW I HAVE TO PREPARE .ON WHICH TOPICS TO BE CONCENTRATE MORE.PLEASE GIVE FULL DETAILS OF WRITTEN EXAM.

1643


Circuit diagram of tube light without starter using electrical choke

3637


as a electrical student why should i hire you?

1976


Leakage current,un balance current which relay using for high voltage transmission?

1626


Explain the difference between verilog task and verilog function?

740


In single phase capacitor motor, if the motor rotate reverse direction then how much power will be consumed by the motor and why?

1464


what is transient stability analysis means?

1661


Why induction motor is widely used in industry

2254


george phenomenon of synchronous machine

6940


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

1570