Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

Actually why the transformers ate rated in KVA.?

Torrent Pharma, XYZ,

2 4917

Which type of alternator used in power station?

2 3787

How to select the ratio of neutral ct? Is there any relation in between percentage impedance and neutral ct ratio ?

1 2853

stand by earth fault protection (51G) for transformer rating 2000 kVA,Dyn11,33/0.400 V. LV NCT ratio and necessary resistor and metrosil values how to calculate

2881

what is shunt trip coil? what was the function in rmu?

1 4337

I want to ask a question which i faced during testing of Capacitive Voltage Transformer in AIS. We have measured the C1 , C2 individually , but when we start to measure the total C1+C2 , the testing equipment shuts down and says low loading. Kindly is it possible to find the total capacitance by using measuring device. kindly briefly explain the procedure.

AIS,

1910

Tell me about Tesla.

Tata Power,

1 3766

which type of questions asking for solar companies?

GE,

1647

how much earthings are provided for 22KV HT Metering Kiosk

GE, Gionee, Knight Frank, TATA, Vacmet,

1 4602

Why neutral has to switch on-off with phase in TN IT TT systems i.e neutral should be taken as fourth pole

1 2704

When can we take Neutral as common neutral link?

1721

I have a situation to design sub-Distribution board/Panel meant for feeding power sockets. In the incomer CAN i Take TP MCCB with Neutral Link and All the outgoing feeders with to sockets with TP MCCB and Neutral Link? P.S : My System is IT Earthing

1884

when we have to purchase the transformer by own i.e how much load will preferred HT connection?

Power Square,

1726

Calculation for the adequacy of 380 KVA neutral earth flat size

Electrical,

1 2794

how to Select Lighting arrester? What r the parameters to be considered for the selection of Lighting arrester ?

1793


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

i have 500 amp inductive load of motors ,,,pleas tell me how can i calculate for capacitor bank for improving my power factor to 99 .....calcullations for capacitor bank,,,,

1675


What is the most accurate way of testing ELCB?ELCB is better than RCD?

3394


howmany electrician should maintain for a 1000 kva used plant... in kerala..

2164


what do you mean by plant earthing system.

2136


What is the de rating factor of cable? What is the importance of the de rating factor in cable select

2452


1600 KVA ka transformer hi aghar lt side par 800A aur voltage 420 ho to HT side ki cable ki rating keya ho gi?

2126


If I bring a basic electric meter from the States and hook it up in Costa Rica in a development that has only one transformer for the 50 homes, will it still be accurate regarding the usage of kilowatt hours?

1982


Who many reason of ignition fail ?

2025


What does the term power factor shows?

1193


explain me the relation between torque, frequency,speed,voltage and current in the 3 phase induction motor?

2306


I want to know the 'Test voltage' for Tandelta testing of 3.3 / 6.6 / 11 KV Motors. Please explain

2319


How to Decide(calculate) Bush bar size for copper and aluminiam ?

2189


State thevenin’s theorem?

1173


is it necessary to earth the rmu before cutting off the transformer winding?if yes why?

1994


Dear all, how we select the cable size according  to current with or without including different correction factor , is there any direct method for sizing of cable... 

2223