Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

how to calculate voltage regulation?

Qtech Software,

1 2860

if negative of DC supply used and positive is grounded through EGB, and if ELCB used in the system then is it sense the positive volatge and get tripped is it possible?

Delta,

1868

why should small green grass ans small plant should not be there inside the transformer Yard in the factories

Riddhi Siddhi,

1757

why a tester wont shock while testing the power in house

Tessolve,

1854

i have a 1500kVA transformer what is the kWH meter i need to use?

HP, L&T, Mohammed Harasani Architects,

1788

Is necessary Protection CT, CLASS - 5P10 fitted at Incomer side of main Breaker ? Why ?

1 2444

What type interview questions ask in Electrical technicians

1796

ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?

2021

Hi, I'm running plastic reprocessing company where all motors are running only in delta. Due to that when I use start my 30 hp motor my transformer gets fuse. Where it happens two times a day. I gt a suggestion from a person about Automatic Power Factor Controller APFC. Is it useful for my problem??? Or is der any other way for solving this problem?? Upgrading the transformer is difficult. Pls give Me ur suggestion. Waiting for ur reply.

Shree Lingaa Polymer,

2 2929

V.c.b and a.c.b difference

4 4340

why Lightening Arrester Probe sharp at Top of telecom tower.

Reliance Jio,

1557

What is the meaning of loop in transformer

AST,

1795

can we use NPT glands in LT panel

1841

If our power factor is lagging then who is in profit? I mean consumer or Supplier!

Sail,

1 2890

What is the unit audit? if our Max demand is something and we found much more unit then how to improve our max demand?

SRM,

1952


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

please send the last 5 years {{{JUNIOR ENGINEER - ELECTICAL, ELECTRONICS RRB CHENNAI and secundrabad}}} TECHNICAL question papers TO MY EMAIL ID dinesh100701@gmail.com

2191


Why an ac solenoid valve attract the plunger even though we interchanges the terminal? Will the poles changes?

1215


Where I can get the sample question for post of Junior engineer electrical-II For RRB Bhubaneswar.

2180


in 6.6 kv vaccum circuit breaker vaccum bottole vaccum capacity ????

2010


how to calculate fuse rating for a motor

5653


What is the implications when 600 hp motor is started when the unit is running with Transformer of capacity 1500 KVA and DG set of 1000kva

2215


how to maintain frenquncy with syncronising sub-station for distribution

2131


how hydrogen cooled alternator undergo maintanence ? that is hydrogen when come in contact with air can result into explosions .

1916


What is acsr cable and where we use it?

1158


What is the Designing & Selection Procedure for a DG/Transormer of rated capacity?

2183


y we use neutral,all r told its used to for closed path..k its a just used to closed path,in a transmission line y we put same conductor used n both phase and neutral..if we use less than phase conductor in neutral mean we ll reduce cost its right r wrong..if we use mean any problem occur in transmission line..

1988


i want to apper for apgenco or aptransco or related can any one sugest me where can i get previous papers of thouse exams

3318


WHAT IS IM (INDEX OF MOUNTING )IN MOTORS

2038


What is the different between conventional MCC and intelligent MCC? Common controller or controller for each bucket

1069


What is open delta Xformer? It's adavntages & Use?

2232