Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Civil Engineering Interview Questions
Questions Answers Views Company eMail

What is the finess modulus of sand?

19 60131

How to calculate the Water cement ratio of reqiured compressive Strength of concrete?

11 72383

during earth quake base shear force=a/w*g Comment?

Power Grid,

2 8060

In case of a beam ,main steel is provided along the longer span because, bending moment is directly proportional to length but why in case of one way slab main steel is provided along shorter span while as bending takes place along longer span?comment

Power Grid,

5 12293

In case of a beam ,main steel is provided along the longer span because, bending moment is directly proportional to length but why in case of one way slab main steel is provided along shorter span while as bending takes place along longer span?comment

Power Grid,

8 22445

why there is need to provide shear reinforcement?give the basic reason?

JMC, L&T, Power Grid,

9 69107

Civil engineering material testing Standard results

SUCG Infrastructure,

2353

How much do you want salary?

L&T,

13 25377

What is construction joint and expansion joint in CC pavements

12 35781

Reinforcement details at hinged joint

3152

where we provide hinged joint in a framee structure ?

3 8598

what is anchorage? Why anchoring of reinforcing bars necessary and what are the shapes ?

6 36578

In olden days reinforcing bars in concrete are not got rusted even till now. But recently provided steel getting rusted in concrete. what are the probable reasons?

11 17097

what are the basic parameters considered in designing a pavement?

5 10947

what is lifespan of an RCC structure? Why the RCC structures failing in quater of its life span?

13 67160


Post New Civil Engineering Questions

Un-Answered Questions { Civil Engineering }

The internal dimensions of a wire house 15m*5.6m and the maximum height of piles is 2.70m. What is the maximum number of bags to be stored in two piles ?

2231


How much is the cover for slab?

1288


What you understand by building codes?

1154


I am called for interview from north east power plant .so, I need some interview question which may help me.

1789


What is the diameter of the 3"inch nails?

2061


Why should you consider yourself fit to be hired by jindal steel.

4432


what is Short bored pile foundation.

2734


Why are separation membranes used between concrete pavement slab and sub-base?

1390


Laying bitumen concrete 40mm thick using 0.1372 cum of 13.2 10mm metal ,0.2387 cum of 10 5mm metal...what did it means please explain me how much cum of 10 mm metal need?

1882


How much cement is require in one sqft area in a G+3 residential construction.

2116


How can i display 5 asterisk and another 5 asterisk )?

2512


How to make a c++ program that converts any base to base 10?

2068


Design a cantilever slab to carry a live load of 2000 N/m2. The overhang of the slab is 1.20m. b) A slab over a room is 4.75m x 4.75m. The edges of the slab are simply supported and the corners are not held down. The live load an the slab is 300 Kg/m2. The slab has a bearing of 15cm. On the supporting walls. Design the slab as per Rankine - Grashoff theory. Assume weight of R.C.C. = 2400 Kg/m2.

2859


As we know that steel is a tension member but why we are using STRUCTURE STEEL as a COLUMN (Without concrete) where column is a compression member and compression strength of steel is very low

1653


a solid steel rod length 2m dia and 20mm vertically hangs from celling and has a collar firmly atteched to it. above the collar an annular rubber washer of 40mm th. having stifness k = 5n/mm is placed. determine maximum stress in the rod caused by mass of 5 kg falling through a height of 1.2m.

2361