Dear friends, I have a question: We work on a project which has some boilers to provide steam for desalination unit. The boiler area is safe and the only hazard source is the fuel lines of boilers. I want to know according to NFPA standard which type of instrument should be selected on the fuel line: Eex Type or Non-Eex type? Thanks in advance
2 4803we have level transmitter for h2s04 storage tank capacity 10k ,always there are failure of transmitter due to failure of magnetic floats ,please come up with solutions at the earliest.
2064what is the different between plc and dcs ? I know full name of this two but I want to know what structure and working style and speed I/O capacity and controller difference?
L&T,
2 16169How to calibrate DP tramitter in flow measurement application? consider my range of flow is 0 to 2000 kg/hr ? please give calculation of , How much pressure applied on low pressure side and high pressure side please give detail of calculation .... It so important for me please reply as soon as possible
1 2839WHAT IS SMART SENSOR AND DIFFERENT B/W SMART SENSOR AND SENSOR??? PLS GIVE ME ANSWER AS SOON AS POSSIBLE.....
1 5078Post New Instrumentation Questions
Draw a group of instruments interlocked to a Pump & Motor?
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
How do you identify between actual alarm and false alarm in a Temperature Transmitter in SCADA based Control System
why is not useing in boiler skin thermocople
What is the GK Value in Flowmeter?
What is Positive Calibration and Negative Calibration?
How to erection of DCS Panel at site step by step
Give Detail information about plc,dcs,and scada system?
any body who gone thru recent iocl interview.INSTRUMENTATION questions. I need.
how will you check torque value during Factory acceptance Test for control valve/ESD ON/OFF VALE how will you confirm this torque value is being correct, Which document will you be refer.
Q- Control problem are mainly classified in _____ types. a-)4 b-)3 c-)6 d-)nono of these Few of them i know is 1- regulator type problem (eg- Air conditioner) 2- tracking problem (eg missile trcking problem) 3- sybernatics 4- optimal control problem
what different types of problems do occur while doing instrumentation commisioning and how to solve them? please explain in detail
How ejector(or)evactor air pump is working in thermal power plant?
Coal mill Instruments Equipments for cement plant And process diagram ?
what is the difference between active & reactive power?