Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

Why in turbine used two critical speed band ?

Ankit Metal Power,

1 4274

why gray colour is choosing to all instrument panel.why not choosing other colour?

Reliance,

1 5144

How we select the range of level transmitter in closed vessel ?

Rosemount,

4 5592

why the output sugnal is 4-20 ma and not 4-25 ma?

5 7699

I have transmitter of range -20 to -5 kpa.if it is possible to zero trim with atmospheric pressure,means HP and lp having no pressure...what will get after zero trim and it is the right way.....plz give me reply ....

KOC,

3 5259

How to find the range of DP cell Transmitter for measurement of level in closed vessel.

Rosemount,

3 5344

How to work mass flow meter ?

1 3811

How to work ultrasonic flow meter ?

1 3691

What are the cable come out from the paddle type flow sensor.and how is further connections

1 2828

What is difference between reset and initialization in system.

Marafiq,

1 4189

Where should we terminate the shield and why?

OPaL,

3 5719

Regarding , there is an air cooler which control the fans(50% of AV FANS) by temperature in outlet , and the louver of Air cooler is controlled by HIC from control system , So if on Air cooler we will consider 2 individual I/P converter or positioner?

Chagalesh Consulting Engineers,

1828

What is the different between of rtd and thermocouple ?

6 7684

what is cavitation in control valve? & how we can avoid it?

Forbes Marshall, Reliance,

1 5358

why 4 to 20 ma used at 0 set

Borouge, Yokogawa,

2 5207


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

Manipulation of dead wt. tester double piston type.

2116


what is thermo coupler and how it works

6184


on interface level transmitter model(RTG3302-EMERSON) What is threshold valve how can we select correct threshold value T1,T2,T3,T4 When interface water & hydro carbon

2218


How digital input and digital output 's are working in dcs

2591


Which is the best field foundation bus. ( FF ) Yokogawa, Honeywell or others ?

1849


How to Calibrate Temperature Switch in field

1368


Why upper weighing limit of electronics balance is 90% of the total weighing capacity?

2255


Explain the working of an enraf level gauge.

1149


give me all the details about the interview and which type of question being asked

2270


What is the purpose of the analyzer in petrochemical plant?

3933


can you provide me full detail about instrumentation in ONGC??

2220


In apron feeder how TPH is calculated?

1794


How can test or measure the probe and extension cable to identify if the problem at the probe or cable or at the driver it self? (pleast notify the measuring method)

2649


describe flow nozzel principle?

2575


we are having yokogawa centum cs3000 dcs in our power plant. i need some of the operator guides NOT to appear in HIS0163 AND HIS 0162 but it shoul appear in HIS0164 HOW TO DO IT?

2650