Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


What is principle of Polarimeter?

Answers were Sorted based on User's Feedback



What is principle of Polarimeter?..

Answer / sivasakthi

light passed through tube

Is This Answer Correct ?    11 Yes 50 No

Post New Answer

More Analytical Chemistry Interview Questions

why we are using buffer solutionas as a mobile phase in hplc.

2 Answers  


what is the need of calulation of RRF of impurity in HPLC analysis?

9 Answers  


Dear Sir, This is Thirunavukkarasu am working in Ordain Health Care AR&D, Am Having one problem While doing method development my question Metadoxine and Pyridoxine same chemical nature and structural activity i tried lot of methods but Analyte eluted same Retantion time i cant separate both peaks. solubility, pH both are same only only difference melting point metadoxine 210 C Pyridoxine 102 C please do the help needful for me

5 Answers   Ordain Solutions,


What is the diffrence in japan mkt requirement in analytical method validation over US?

0 Answers  


If we have a kc is1*10^8 and the .kp 2*10^5 of reaction A------->B C------->D what is the volume of C?

0 Answers  


what is Hilic chromatography?

1 Answers  


What is void volume & dead volueme

3 Answers   Bayer, Lupin,


why we get negative values in uv when i placed sample which has some concetration but not in standard

1 Answers   Nirma,


what is dissolution What is unit of KF? what is the significant of pH in HPlc? WHY POTASSIUM HYDROGEN PTHALATE IS USED FOR PERCHLORIC ACID? What is difference btw UV detector & RID detector?

1 Answers  


What is Delay & Dead Volume

2 Answers  


What is use of LOD and LOQ in validtion and give range and in calculation why we use 3.3* LOD here why we use 3.3

2 Answers   Dr Reddys, IPCA, Reddy Labs,


what is specificity?

4 Answers   Amneal Pharmaceuticals, Aurobindo,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)