state and explain in Water absorption of brick
Answers were Sorted based on User's Feedback
Answer / shabarish
Water absorption of brick is nothing but the % of water
that the brick can absorbs when it is placed in water.
It isshould not be more that 15 to 20 % of its weight.
| Is This Answer Correct ? | 148 Yes | 18 No |
Answer / prakash
The water absorption of brick is the quantity of water
absorbed by the brick when submerged under water for 24 hrs
expressed as % of its dry weight.
| Is This Answer Correct ? | 47 Yes | 6 No |
Answer / nanthakumar.c
As per IS 456 2000 If brick is subbmerged in water for 24
hours its weight should
not more than 20 % of its own dry weight
| Is This Answer Correct ? | 33 Yes | 5 No |
Answer / devendranchandrasekar
During the time of manufacturing bricks mixture of minerals
like silica, clay,ash,sand,etc this propotionate should
vary in all every production and also watercontent plays
very major role in the bricks
as per IS CODE SAYS 15 TO 20 PERCENT is the max limit of
water absorption brick in 24 hrs
water absorption in bricks depend only voidratio of bricks
and also poor compaction ,
well burnt bricks it should be burnt on all sides equally
good shape also all dimensions should be in proper and
clear
| Is This Answer Correct ? | 31 Yes | 7 No |
Answer / sonu
it also depend upon the pre moisture content by bricks
| Is This Answer Correct ? | 33 Yes | 14 No |
Answer / rakesh kumar
brick is su8bmerged in water for 16 hours its weight should
not exceed more than 20 % of its dry weight
| Is This Answer Correct ? | 29 Yes | 14 No |
Answer / rabitha panat
As per IS:3495,the average water absorption shall not be
more than 20 persent by weight upto class 12.5 and 15
persent by weight for higher classes in 24hrs.Bricks,which
do not conform to this requirement shall be rejected.Over
or under burnt bricks are not acceptable for use in the
works.
| Is This Answer Correct ? | 17 Yes | 4 No |
Answer / kavitha
water absorption of bricks depends on classification of
bricks.
for first class bricks water absoption should be less than
20% and for second class bricks it should be less than 22%
and for third class bricks it is less than 25% by dry
weight of bricks
| Is This Answer Correct ? | 20 Yes | 9 No |
Answer / pankaj kumar sahu
What will be the strength of different type/class of bricks
as per Indian Standard?
| Is This Answer Correct ? | 6 Yes | 1 No |
Answer / pankaj kumar sahu
Please clarify the classification of bricks as per water
absorptions as per IS Codal provisions.
| Is This Answer Correct ? | 5 Yes | 1 No |
Brick is fire resistant than stone because––
What is the procedure to calculate the compaction of sand?
Concrete could be defined as, (1)An artificial stone (2)Structural stone (3)Strong stone (4)Rock and Sand stone
The largest size of paper used in plotter to print the drawing made by Autocad .
how to calculate quantity of cement and sand for plastering works in CM 1:6 proportion.....plz answer anyone.....and write the formula...
I have certain queries, please help to solve. a) length of pile bore is 4m.excavation quantity will be area * length where area will be pi/4 * dia*dia. Is this right? b) It is a single reamed pile of 300m dia and reamed dia is 750mm. can any body help me to calculate excavated quantity of this bulb(reamed section),, concrete quantity in bulb with showing the formulas to be used?
when we workout quantities of reinforcement steel , whate are the critari of lap length for column
what type of cement are used for fixing of tiles at floor/wall
wat is fe full form in fe4l5?
beam top main reinforcement(25mm) was drilled off by mistakely when making drill hole for dummy columns. any one can give useful information for this issue or related code or websites.
while doing the structural works of a simple ground+1 villa, can the columns be continued immediately after neck columns without tie beam, while the tie beam to be done after columns concreting.
my client's 10 year old building have been affected by the neighbor new building construction with out set back.Old building cantilever bldg hanged by 3". It is supported by introducing 2 rcc columns & beams.Now how to conceal the cracks?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)