errection check list for transformer maintenance


No Answer is Posted For this Question
Be the First to Post Answer

Post New Answer

More Electrical Engineering Interview Questions

What is Procedure the procedure to select CT's & PT's in 66kV and above substation

1 Answers  


hey guys i scored 910 on GRE and 67 on TOEFL respectively.I have an aggregate of about 74%in my B tech.For which colleges should i apply for an MS program in electrical engineering.I am looking for colleges in NJ,SC,NC,GEORGIA, NY. Please reply with a good response.....

0 Answers  


How to control motor gearbox speed and friquency? If length of cable and dia given, how to measure the voltage drop?

0 Answers  


DIFFERENCE BETWEEN TRANSFORMER AND CURRENT TRANSFORMER?

7 Answers  


1.Whats the use of GNAC(Generator Neutral Accessory Compartment) 2. why generator or any other system require Neutral Grounding and not Phase grounding 3. what happens if any one of the phase is grounded. 4. if 15kv is grounded directly what will happen, why it should not be grounded like that 5. use of of NGTR(Neutral Grounding Transformer and Resistor) for grounding is helpfull and how

5 Answers   BEMCO, CSS, Powergear,






Why the motor take high starting current for long time(10- 15 sec) which is connected to Blower as compaire with a motor which is connected with pump with same rating?

2 Answers  


Can we parallel lise the secondary side of the two similiar transformers with same voltage ration, imp, but with different vector groups.. ( for ex. 11 KV / 6.6KV two trfs but different vector groups can we parallelise both of them ,, what happens if we parallelise them

1 Answers  


What is zero of the system?

0 Answers  


how much cuurrent flow through human body effected ????

7 Answers   Divis Laboratories, ICSA,


How to calculate the Efficiency of Chiller

0 Answers   Knight Frank, L&T,


I am new guy as an electrical engr. in a 100MW HFO based power project. I am in operations division. I have noticed from last few days, my supervisor sends the last 24 hours energy generation calculation to my plant manager. I have noticed, he calculated last 24 hour's generated energy differences in KWH then he multiplied it with a multiplying factor 960. for example: total difference =2.685 KWH*960= 2577.6 MWH. but he does not not know what is multiplying factor 960?? can anybody explain it??

1 Answers   Orion,


How will polarity test of Dy5 transformer ?

2 Answers   BSL,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)