Why the core of a underground cable is spiral in shape instead of straight??..

Answer / ranga2k8

In order to increase the ruggedness & thereby mechanical
strength of cable, it will be made in spiral in shape.One
more reason is we can bend the core whenever a sharp curve
is needed in the erection of cable.

Is This Answer Correct ?    10 Yes 1 No

Why the core of a underground cable is spiral in shape instead of straight??..

Answer / gurucharan singh

this is to increase the strength of cable core. As cable
core is amde of multiple small size wires called strandes.

Is This Answer Correct ?    9 Yes 2 No

Why the core of a underground cable is spiral in shape instead of straight??..

Answer / j_diyym

I imagine its the case with all cables; is purely for
mechanical and practical consideration. nothing electrical.

Is This Answer Correct ?    0 Yes 1 No

Post New Answer

More Electrical Engineering Interview Questions

What are the types of AMF(auto main failure) panel.

1 Answers  


in GEAFOL Cast-Resin trnaformer of 11/.72kv which has tapping of 11550v,11250,11000,10246v in primary side. To obtain 700v. which tapping should be used of HV side as we have 11000v/720v tapping now .

1 Answers  


what is the relationship between phase & neutral

0 Answers  


what is self commutation how a thyristor discharges through a capacitor and inductor

3 Answers  


How does a ideal c.t. works ?

0 Answers  






11 KV distribution system where neutral is produced ?

4 Answers   ciss, TATA, Tata Motors,


how to size H.T & L.T Panel ?

0 Answers   Schneider,


In an panel board if the outgoings are power plugs and motor equipments...what should we choose as the incomer of the of the panel board?? MCCB OR ISOLATOR?? Should we use ELCB protection??if so where??

2 Answers  


cany anyone suggest electrical wesites for providing study materials?

0 Answers  


what is use of starter motor in DG ?

2 Answers  


Even when a particular generator in a generating station is under maintenance we are still able to maintain the same power output. How is this possible? Does the tie line between 2 generating stations have a role to play in it?

1 Answers   NTPC,


How to size the Neutral grounding resistor?

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)