HOW DOES THE FAN REGULATOR CONTROLS ITS SPEED
Answers were Sorted based on User's Feedback
In electrical regulator by using resistance the output
voltage is varied simultateneouly the speed is varied...
But to reduce the the energy loses in the resistor,
electronic regulator is introdueced,which uses triac to
vary the output voltage by varing the firing angle.Which
avoids lose of energy in resistor...
Is This Answer Correct ? | 155 Yes | 17 No |
Answer / ayyappss
Conventional fan regulator works by the principleof
auto-transformer.
now in modern regulators we using triac to control i.e,by
varying the firing angle, output voltage is varied then
automatically speed can be varied
Is This Answer Correct ? | 117 Yes | 27 No |
Answer / saurav
The circuit works by varying the firing angle of the Triac..
output voltage is varied then automatically speed can be varied by this..
Is This Answer Correct ? | 20 Yes | 2 No |
Answer / bhanu gupta
Fan regulator working based on the principle of power control using a Triac.The circuit works by varying the firing angle of the Triac . Resistors and capacitor are associated with this. The firing angle can be varied by varying the value of any of these components. Here register is selected as the variable element . By varying the value of register the firing angle of Triac changes (in simple words, how much time should Triac conduct) changes. This directly varies the load power, since load is driven by Triac. The firing pulses are given to the gate of Triac using Diac.
Is This Answer Correct ? | 3 Yes | 1 No |
Answer / nk
Electronic fan regulator is an electronic device consisting
of diacs, triacs, potentiometric resistance to provide
stepless control of fan speed. This is an energy saving
device and has advantages over the conventional type of fan
regulators having more energy losses.
These regulators can also be used as a speed regulator for
many other small F.H.P. motors used in mixer, laboratory
solution mixer etc.with appropriate current ratings.
Is This Answer Correct ? | 18 Yes | 21 No |
Answer / vatsalsharda
by changing the number of turns,flux linkage changes and
thus induced emf changes
Is This Answer Correct ? | 8 Yes | 43 No |
im working in one private compeny in gujarat. i was complet diploma electric in 2010 from gujarat technical board. now i want electric supervisor licence in gujarat but i dont't know when i apply? plz give me address of the licence dippartment office in gujarat. gandhinagar
For a three phase induction motor, what will be the effect on motor if the neutral of the system is shifted to say 20 deg.?
starting torque is increased and current is decreased by using external resistance in a slip ring induction motor. How??
How we can change the direction of rotation of Induction motor? Prove it using graphical
How to set an overload in a motor?
why alternator is used instead of dc generator and induction generator
what is alternator?
what is specific gravity of a battery if specific gravity increase/decrease,what will happen to the voltage/current of the battery
when we gave dc supply to 220v dc motor its rpm is 1200. then we gave 180v. how many rpm of its motor. gave answer with calculation at my ID.... ravizak@ymail.com
can I connect 25KvA stepdown transformer(RYB-440V,UVW-240V) to the output of 15KvA,3-phase online UPS(440V phase to phase)please brief.
what is the cable size we can use for 11kv and 33kv ?
what is power