Answer / piyush singh
Spacer bar are used to maintain the depth of the bars as per the design, also the size of the spacer bar should be such that the coarse aggregate should pass between the two layers of the Rebars,
So if in concrete 20mm aggregate are used then spacer bar should be of 25mm size so that aggregates can easily pass through it
| Is This Answer Correct ? | 6 Yes | 0 No |
Write down a formula to calculate the number of 50Kg bags of cement for moulding of cement blocks of tcm thick by 20cm high by 40cm long on site with a mix ratio of 1 bag of cement to 3 wheelbarrows of sand . the sand is measured at a STRUCK( WATER LEVEL) 65 litres capacity wheelbarrow. TEL: +237 674630019
01m3 cement mortar in cement qty in kg
I want some common questions which have been asked in interviews of NTPC Limited,Satluj Jal Vidyut Nigam Ltd.,and Bharat Heavy Electricals Ltd.
In an aggregate blending plant, water is sprayed before blending is performed. If the fine content in aggregate is as high as 25 %, will not the fines form into lumps / balls and distribution will not be uniform ? Further, the fines will stick onto the interior of pug mill and its content will be low. The mixed material is stockpiled for weeks / months before use. Will it not be better that blending is done in dry condition, and water will be added only during compaction at site. Please forward your comments and suggestions.
if i have to draw bending moment diagram of 4 way continous span then how to create it and how to find reaction?
8mm steel not available at site used bar 8mm and 150cc please tell me specing i used 10dia bar write formula please
what is the requierd compressive strenth for m 20 grade concreat for 7 days?
how to calculate the quantity of steel used for construction..
What do you mean by Hydraulic Piling??
Heat gain in buildings is best resisted by
6 Answers AIEEE, B Arch, JMC Projects, Unique Dream Builders,
how to calculate the volume of water in the water tank (5'x5'x5')? what"s the formula?
15 Answers Fire Safety, MAHINDRA, New Star Construction, Shankar Electricals,
in 2 way slab can additional compressive reinforcement can be provided if yes than in which conditions it is required ?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)