what is the difference b/w UHVDC and HVDC(LIGHT)?

Answers were Sorted based on User's Feedback



what is the difference b/w UHVDC and HVDC(LIGHT)?..

Answer / hari krishan

Ultra high voltage Direct current(UHVDC) and High voltage direct current(HVDC).

Is This Answer Correct ?    1 Yes 0 No

what is the difference b/w UHVDC and HVDC(LIGHT)?..

Answer / thangaraj.r

UHVDC is above 765kv ,HVDC is above 440kv to 765kv.
HVDC line is placed all over the world .But UHVDC is placed
only in BRAZIL and JAPAN

Is This Answer Correct ?    1 Yes 0 No

what is the difference b/w UHVDC and HVDC(LIGHT)?..

Answer / jawad

i need to know the technical difference? not abbreviational

Is This Answer Correct ?    0 Yes 0 No

what is the difference b/w UHVDC and HVDC(LIGHT)?..

Answer / jawad

dear Thangaraj.r
kindly tell me, one thing more, what is the basic internal technology used in UHVDC, as thyristors are used in HVDC and IGBTs are used in HVDC PLUS

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

How Many Safety of Transformer

2 Answers  


what is thyristor, how is it works

1 Answers  


Why we transmit the power at the voltage in the multiple of 11 or 1.1 like 11kv, 22kv, 66kv, 132kv...... some one told me that it is due to fomr factor 1.1 of sine wave. its fine but while transforming we can choose any voltage, so why only multiple of 1.1 there also.......? plz tell me.

7 Answers  


what is main difference between live tank and dead tank current transformer?

2 Answers   Atul,


why we are using DC supply in megger?

3 Answers   TATA,






why the active power flow of some line is increased when the active power of out is cut ?

0 Answers   TAFE,


what is mean by hormonics & surge? and it's effects?

1 Answers   TCS,


I WOULD LIKE NOW WHY WE CANT USE SOME CT FOR MESARING AND PROTECTION

2 Answers  


in slip ring motor if motor specification is given how we calculate its rotor resistance in starting

1 Answers  


what is the difference between synchronous & asynchronous generators

1 Answers   Emco,


Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir

0 Answers  


what is the maximum permissible limit value of leakage current and leakage counter reading to replace lightining arrester?

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)