What is the difference between Autodesk revit structure and
STAAD pro.? How much it is useful to structural engineer in
modelling, analysis & design of RCC and Structural steel
structures than STAAD pro.?
Answers were Sorted based on User's Feedback
Answer / gp
Revit structure is a Building information modeling software
especially used for structural analytical modeling so that
it can be exported to major design and analysis software.
This eliminates the necessity of creating analytical model
in a design software. Apparently, Revit structure is not a
design/analysis software. But it is not only used for
exporting to design. Building projects can be completely
modeled with all structural and non-structural elements and
the general arrangement drawings (2D & 3D views)can be
exported to AutoCAD for further use like detailing if
required. Sectional and Elevation views can be extracted
from the model anywhere and at anytime within seconds.
STAAD pro - as far as I know, is used for design and
analysis.
Is This Answer Correct ? | 35 Yes | 4 No |
Answer / akash yadav
staad pro is a structure analysis and design softwear its only design a frame structure its calculate load quantity of steel and sfd bmd diagram but revit is a designing softwear those main banifit is make a design in 2d, 3d is design automaticaly doing work easily and fast is compaire than other design softwear both ( staad pro and revit) is needed a structure design
Is This Answer Correct ? | 2 Yes | 3 No |
Answer / chaitu_nitn
I think it is not much useful to structural engineer in
analysis & design comparing with STAAD pro.
Is This Answer Correct ? | 8 Yes | 19 No |
What does 'M' stands for in M24 bolt ?
What is the weight of 10mm,20mm,40mm aggregate per cubic ft in kg?
5 Answers Akasva Infrastructure Private Limited, L&T, NCC, Virchow,
what is meant by residual strain?
Can compresive strength test for concrete at 1 day age possible to carry out? If yes, which IS code describes the procedure for such testing?
what is the proportion of stones and concrete inplum concrete??
I have an span length 16 ft c/c
1. HOW MUCH CEMENT AND SAND REQUIRED TO PLASTER 100 SQM WALL. 2. HOW MUCH CEMENT AND SAND REQUIRED FOR SCREED WORK OF AREA 30 SQM
0 Answers Civil Service, Intelinet, Marg, PMC,
whether earth to the height of 80cm could be filled in the basement inm place of jamuna sand
Difference between wbm and gsb in road construction
4 Answers CPWD, GSB, Ircon, JMC Projects, L&T, RD,
how many cement bag in 1m*m*m
we have a crushing plant and our product is experiencing flakiness and elongation over limit for granite. what is the solution to this problem? how can it be avoided and what to do differently? It is not ok for batching plants
i m searching for steel or rebar weight/meter (d)2/162 this is correct but why used here 162