Engineering AllOther (1379) Is it good to short Neutral and Ground in the PLC or DCS main Power supply. Pls give YES or NO with reasons...? Simarpreet
2543i have a Connected Load of 280KW and Maximum Demand of 224KW to one of SMDB under design with me. which criteria should i consider to design panel and main cables connected Load or Maximum Demand 1)Breaker rating 2)Panel Busbar rating 2)Incommer cable sizing (ignore Voltage drop)
1 5482Dear Mr B C pal...Can you plz. put some light on principle of operation of Z-Ct in conjunction to its use with 1Cx1000Sqmm HT Cables & Directional Ground Fault / Over Voltage Relays...Regd..Parag v K 9899115632
2763How does a chemical get ignited without external heat source on reaching its auto ignition temperature
1 4238Initially motor starts with star connection ,after few timing changes to delta connection, why the motor should run continously in star connection,it gives high torque & low current?
3 9556
how to calculate the battery AH
Explain what is ply yarns?
What is the use of each wire in three wire RTD
what are the components in electrical control panel (for example: 415V, 3-ph, panel to operate utility and 3-ph DG set).
Can we use Ccapacitive voltage transformer directly for metering purpose?
What is oneside mat. And explain
What is the circulation of I.O. pump of diesel engine?
Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.
at what base you will tell the direction of rotation of dc motors and generators?
Hi i'm richa piplani applied for ATC(IT) if u have the syllabus & old question papers forward me.I will be very much thankful to you. piplani.richa@gmail.com and sonu_pips@yahoo.co.in
What does a rolling offset look like?
Discuss advantage of different types of screw.
"How to check the diode, fuse and bearer switch?"
Whether it is possible to measure energy at the input of rectifier transformer (12 pulse with very high odd harmonics)
why wire sizes are 3/29 or 7/29 and why not wire sizes are 2/29 or 6/29?