Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...



Engineering Interview Questions
Questions Answers Views Company eMail

plz send me interview questions for POWER GENERATING CORPORATION LIMITED. my mail id is "ajaymits2004@yahoo.com"

1899

Telecom BSS related ques: For cascaded 1800 BTS with master 900 BTS,if 900 master BTS is down for its own equipment fault,cascaded slave 1800 BTS gets down/stop carrying traffic without any fault as BCCH and other controllong channels are in master 900 BTS.Is there any technology/system to turn the slave 1800 BTS to a single 1800 BTS autometcally when 900 master BTS is down for its own equipment fault???It is possible to make the slave 1800 BTS single live BTS manually.But I want to know the autometic system/process.if there is any....if not available, how can we generate the system??

Ericsson, Grameen Phone, Nokia, TATA, Telecom,

3 16250

what is the function of generator exciter

NTPC,

11 68737

why dead weight tester called dead weight tester.

QAFCO,

5 24736

One of the advantages of HRC fuse links is that they can be used to back up equipment with an inadequate rupture rating. briefly discuss what this means

1 5834

What is meant by the KA-rating of a circuit breaker? In this regard, discuss the stresses experienced by the circuit breakers

3 14016

Hi, please share APGenco Assistant Engineer (Mechanical) model question papers.

APGenco, DBS, Essar, KTPS, L&T, Tikona,

8 25292

WHAT IS THE DIFFERENCE BETWEEN KW AND KVA ?

10 34343

Whats the difference between uniaxial column

8 61696

WHY THE WIDITH OF COLUMN IS TAKEN FOR DESIGN OF ISOLATED FOOTING??

L&T,

9 17921

In Battery Charger - What is the meaning of End Cell Voltage and Float Voltage.

FLSmidth, Focus, PSEB,

9 43034

sir i have 57% in inter and engg having also 57% sir.now a days companys offering above 60%,but i have less percentage what will be do now,can u help me sir,plsssssssss

1 3714

How to Calculate the maximum Demand required for a connected load for a manufacturing Plant

6 82133

How to design harmonic filter at the project stage without nowing the harmonics levels

2219

How to connect a Restricted earth fault relay for 2000KVA,11/0.433 KV Distribution Transformer and What is the neutral CT ratio should be selelcted for 2000 MVA Transformer for estabilishing the Restricted earth fault relay

1 4126


Un-Answered Questions { Engineering }

what's producer of XLPE cable laying in undergroung

2134


Explain how are vessel lined with glass or how are they coated?

1111


What is the use of generics? when was it added to jdk?

2095


what is the exact dia of 8swg and 10swg gabion wire

2328


Explain the advantages and disadvantages of hydropower plant?

1137


Define positive logic and negative logic.

1025


How you calculate the repturing capacity of a HRC fuse

2627


In case of a constant mesh gear box, when the left dog clutch is slid to the left by means of the selector mechanism, a) Direct gear is obtained b) First gear is obtained c) Second gear is obtained d) Reverse gear is obtained

1302


For what purpose bedding is used under storm water drains?

1121


What is stripper & spilitter ? Diffrence in this.?

3018


what is the max. acceptable leakage current in 33kv bus bar

3023


i have done diploma and btech in EE and live in Chandigarh so kindly help me how can i make my competency certificate in my area.

2223


Differentiate between conductor and inductor.

1040


if a.c supply is given to the motor,, what happen?

2163


what is the preventive maintence for ht panels and busbars and vcb abd acb's.

2386