It is used or not HT cable single core 630 sqmm in LT 3 phase capacitor bank which is used in PCC(power control center).

1 2757

What is two wire system and how it work

Bhel, IFFCO,

2 6241

What is the permissible limit of silt contain in sand for rcc Work?

Ambuja,

7 8341

diesel generator not getting start so whats problems will happen to DG and how we can start DG

Lodha,

1 3970

voltmeter kya hota hy ?

2 4461

electric contractor ya contactor kia hota hy ? or kesy connect kia jata hy ?

1 2824

Why the transformers are rated in KVA ? in new view

3 5314

Boiler capacity is 5ton, what will be the feed water tank capacity?

dscl, Indiabulls, Krest, TCS,

11 16867

Relative Humidity (RH) is mostly used word in Datacenters, What are the defendents of RH

1329

how to calculate the capacity of CT operated LT trivector meters on a particular distribution transformer.

1 3107

which one has maximum efficiency autotransformer or transformer?? and why??

2 5468

how to test reverse power trip?

3887

What is the maximum breakdown voltage of 11KVA and 66 KVA power line and how it is calculated?

Anglo Platinum, Narnarayan Electrical,

1815

What is candidate key ? What is Alter net key ? & What is foreign key ?

Globsyn,

1449

silt%= silt volume/ silt+sand volume is this right?

1515


Un-Answered Questions { Engineering }

MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)

1825


How to test the vector group of a Yd11 transformer? what are the relations to be checked between various vectors to confirm this vector group?

4007


how can be calibrate flow indication transmitter (rosemount) it shows excess milli amps nearly about 24 ma on full scale, but its scale was set on 20ma on full scale..???how can be simiulate..???

2008


What are some good strategies for curing tube vibration in shell and tube exchangers?

669


sir,please send me the questions and syllabus for ongc technical assistant exam for electronics and comm

1903






Explain the function of cyclo-converter?

626


How to set the relay,,??

1633


can anyone please help me to find the rupturing or breaking capacity in KA of circuit breaker (MCCB,VCB,ACB etc) of HT and LT side of a distribution transformer...please help with detailed step by step answer...thank you

1574


how control valve works? process line pressure is 50kg/cm2g and instrument air pressure is about 4 kg/cm2g.

1674


Why should we hire you over the others waiting to be interviewed?

2040


100mm block work 64 bags of cement used 150mm block work 286 bags of cement used 200mm block work 20 bags of cement used patly work (M15) 293 bags of cement used mortar ratio is 1:5 how to calculate volume of sand in cum & no. of bags

2027


What is single input output interface? How it is different from single ended interface?

574


What is the start up procedure of desalter

3049


What are Green Field Projects?

624


5. What is the maximum transmit power of FlexiEdge BTS

1459