Questions :- HR- Q.1 about yourself & family background ? Q.2 Why u choose Power sector as ur carrier starting not any other sector ?? Q. 3 What think abt NTPC ? Techincal Questions:- Q.1 about Vocational Training……What u did , see the main equipments….etc Q.2 Why a transformer Noise during its running condition ? Q.3 about transformer oil material & Test name for the measurement of its dielectric strength & wht will u do if its dielectric strength goes low ? ……..some discussion type ? Q.4 What is relation between transmission lines & Communication lines ? Q.5 Which Machine u will prefer to use at a place where flammable gases are coming out & why ? Q.6 how fault in an electric system is detected & hw protection of equipments is done ? Q.7 Why we didn’t feel electric shock in an electric train ?? Q.8 Anything u want to ask from us ??
44 28378WILL THE PERCENTAGE IMPEDENCE FOR A ONAN TRANSFORMEER BE THE SAME COMPARED TO ONAF TRANSFORMER OF SAME RATING???
5 7670Usually in the L & T make MCC feeders' power circuit,we have BMR after the MAIN CONTACTOR.,can we interchange their position, keeping the control logic same???
1157Why is it that variation allowed in supply voltage to motors is (+ or -)10 %, whereas that in frequency is (+ or - )5 %
3 4473Post New Electrical Engineering Questions
Why 9KV surge arrester having 7.65KV of MCOV?
Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.
When and where resistance earthing is used ? How to calculate the time constant for earth fault
sir i ve applied for hindustan petroleum and power grid india ltd..and the exams on feb 22.can you pls send model papers and tell how to prepare for those.i need to get into any of these for sure.....
what is a types of short circuit and what is a types of distance protection tests
Dry type transformers
How test for Ddo vector group test condition?
explain safety measures in alternator?
How to calculate the size of earth cable to earth the neutral of UPS ?
what is mean by transition resistance of transformer?
What is the ideal position cooling fan inside the dc motor?
what is meant by LCR meter? where its useful ?
How can we increase fuel-power ratio of any DG set?
What consists of 2 or more thermocouples to be connented series?