Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

1600 KVA ka transformer hi aghar lt side par 800A aur voltage 420 ho to HT side ki cable ki rating keya ho gi?

2037

active elements are those which are capable of

2 4100

armature is that part in which current is induced since in dc motor we supply current to the conductor so why we call it armature?

1909

If 110 volts ac is mixed up ith 12 volts dc what will be the resultant voltage and what is the wave form?

1 3403

which transfofrmer oil break down voltage strength get will be more if oil sample taken from bottom of tank or oil sample taken from top of the transfomer tank.

NPCIL,

2 5376

Ceiling fan motor wiring Hi, I have 2 ceiling fans broken. The receiver/control units burned out due to lightening. One Harbor Breeze and one Hunter's I took them apart (remove receiver units). Now on both of the motor I see 4 wires coming out from each motor I really want to know the function of each wire. Are there anyway I can test to see which is which? After searching forums I know these 4 wires are from 2 sets of coils inside the motor, one is Start winding and the other is Runing winding I could not find the receiver/control unit any where, so I am planing to buy Capacitors and universal remote controls to make the fans run again. Anyone has any idea how to do the wiring, please help Thnks

1 2543

exolain the star delta connection

Toyota,

2678

What is the advantage of AC supply?

PSU,

5 7963

why current is leading in capacitor?

PSU,

1 6598

What is the difference between analogue electronics and digital electronics?

PSU,

2 4586

Why generating power limited to 11kv?

PSU,

4 8368

what is hysteresis loss?

PSU,

4 7521

WHAT IS THE DIFFERENCE BETWEEN GENERAL INVERTER AND SOLOR INVERTER TELL ME PLZ

Epcon,

2214

difference between ac series and parallel circuit

2043

what is pure resistive circuit and pure inductive circuit

1 3955


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

how can we change the polarity of Alternating current rapidly? how frequency of ac can be controlled and changed easily?

2018


Can anyone tell the proper diagram of star delta starter????

1930


How you calculate the repturing capacity of a HRC fuse

2621


What do you mean by phasors?

1072


Which material is used for the core of a transformer and why?

1107


Draw a 230kv two-bus bar system showing the following. 1.Two generators (150MW) each connected through one 15.75/230KV transformers 2. 1 outgoing lines 3. Two 230/130 KV transformers 4. BUS PT's 5. CT

2587


What is the use of iron core in a transformer?

1136


why transformer tank is in rectangular shape what happen when it is in step shape

1454


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1795


IF I KNOW THE AREA OF CROSS SECTION OFTHE WIRE , WATTAGE OF THE LOAD ,VOLTAGE SUPPLY WHAT IM GIVING TO THE LOAD AND ALSO POWER FACTOR OF LOAD ....... SO GIVE ME FOR WHAT AMOUNT OF CURRENT I SHOULD USE WHICH TYPE OF CABLE?

1899


CPC cable .PVC \1C....I want to get sure that type is flexible indoor or to be install on trench. please advice .thanx :)

1844


we have 3 single phase transformers. how will we generate 6 supply from 3 phase supply input

2120


What is the percentage loss for aluminium wire for HT line more than 11KVa

2128


How out of step protection relay works?

2440


what happens when series resonance occurs?

1848