What is the meaning of capacity of a 63 Amps TPN MCB? Is it the per phase capacity or the totol capacity?
1 14435Give me the calculation steps to design an electromagnet to be work in 230V 50 Hz AC Supply. Also give force that is created by that electromagnet when it gets energized.
GE,
22143 shows a 415 V, 3-phase generator supplying a 3-phase 415/110 V transformer. Draw the individual and combined impedance diagrams to a base of 10 kVA. Determine the system fault kVA and the fault currents at the 415 V and 110 V busbars for short circuit faults on the transformer input or output terminals. Work in p.u. values of impedances.
2657I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.
1873What is the kiosk parts, about them and their functions ? If anybody have some PDFs files or details about this plz send it on tawhidfaisal@Yahoo.com
1914Post New Electrical Engineering Questions
A 3-phase IM is supplied from 50 Hz system. It runs at speed of 1440 rpm and slip equal to 4 %. Calculate number of pole pairs. A 1 B 6 C 2 D 3
CAN ANYBODY PLEASE TELL ME HOW TO DESIGN A SERIES REACTOR FOR LIMITING SHORT CIRCUIT FAULT CURRENT??
Why the magneti fields are not passes from southpole to north pole
Difference between control junction box (cjb) and power junction box(pjb)?
How do apply electrical 'c'license......pls advice
does a DG set has low fault level as compared to that of a transformer.If yes then why.
What is an alternator impedance value?
66kv under ground cable how to layaing in ground any special case two ckt r runing
What is I to C?
is the value of inductance depends upon the value of thitha in doubly excited machine??
how to test reverse power trip?
IN 1000kva transformer where the oil and winding temperature sensors is connected
how to calculate maximum current
Application Comparison between 22KV (UE)and 33KV (E) system. Are we allowed to use 33KV (E) cable in lieu of 22KV (UE) cable. What are the technical disadvantages.
IF 8255 CONTROL WORD IS 94H,Tell the chip port work mode ?