My energy meter ratio is -/110/root 3,1A and connected line CT is 100/1,PT is 11kv/110 so what is the MF for meter
1 6027A 60w bulb & a room heater are connected in series.if 60 w bulb is replaced by 100w then what will be the effect on heater out & why?
6 16837How will A Medium voltage circuit breaker(11 kV voltage level) operate under short circuit fault condition whether It is having short circuit release like Low voltage circuit breaker or relay should be given?
1995During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.
1986how the CT and PT is connected in the circuit during testing of transformer explain with diagram
KESC,
2071Post New Electrical Engineering Questions
what is consequences of neutral and earth connect?
operation of diesel generator
A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE
in an electronic tri vector meter when the current and voltage sequence changes ? what is the effect of phase sequence on recording of meter
What are the types of windings present in the ceiling fan? What winding will be effective first when we started the fan?What are the resistance and inductance ratios comparatively at the initial speed and full speed of the fan?
If VFD is On but no starting commond on it. so how many outpout voltages of VFD
What is “pu” in ee?
if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit
what will happen reduce the transformer voltage from 415v to 406v, is it save the energy,? are this methodis good to reduce the energy.?
During FEED, you will have all the information with regards to cable. How will you calculate the MTO for MV and LV Cables? what are your considerations?
What cmos is and its benefits?
Why single phase induction motors are not self starting ?
can the measured percentage error during calibration of single phase energy meter be negative?
How to calculate size of HT breaker with the help of Amp (current)? Please provide answers with examples.
Difference between rating factor of cable and derating factor of cable?