Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

Application Comparison between 22KV (UE)and 33KV (E) system. Are we allowed to use 33KV (E) cable in lieu of 22KV (UE) cable. What are the technical disadvantages.

2356

Application Comparison between 22KV (UE)and 33KV (E) system. Are we allowed to use 33KV (E) cable in lieu of 22KV (UE) cable. What are the technical disadvantages.

2815

various transmission tower like .,D tower ,K.C.O tower ,C.C.O tower,K.C.R tower ,C.C.R tower ,H.C.O tower in different tons.

3300

1.ZEBRA conductor(large size) 2.KUNDHA conductor( small size ) 3.panther conductor(very small ) 4.lepard conductor (very very small)

2913

I COMPLITED MY B.TECH AND 10TH CLASS WITH 70%MARKS BUT 12TH CLASS 55%MARKS..CAN I GET INDIAN RAILWAY RECUREMENT EXAMINATION?

UPSC,

2184

what is unit of inductance

Bhel, Bosch, OSML, Vijai Electricals, Voltage,

12 15984

work of choke in florocent tube circuit ?

Bhel,

2134

Does the motor power displayed on the Motor name plate is the mechnical power motor delivers or it is consumed power from the system?

2 4399

I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.

NCC,

2111

A 10 kva ,400v/200V , single phase transformer with 10% leakage impedance draws a steady short -circuit line current of

1 8276

i am an maintenance engineer. one distribution board have 5 feeder. recently its ELR trips frequently, but it take some times after trip( 10min,20min..)but 3 feeder no load. two feeder only loaded. i checked one feeder IR value all values are above 50Mohm.but B phase to Earth is only 9Mohm.any problem about low value

1946

what is the transformer turn ratio formula and give some examples?

UPPCL,

2428

if installing the transformer why put the sprit the stone ?

1 3199

how to calculate the distance relay faulty zone?pls explain?

2046

explain transformer ct connection?

2057


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

bitumar

2308


What is control system?

1207


our factory is going under construction mean time transformer 1000 kva 2 nos &load break swithch 12 kv & 4 nos 750 kva 2 nos & 380 kva 2 nos generator to be errcted.how to arrange earth pits &how to earth connect & neutral pit how to calculate in earth bit size.

2110


HOW WE CALCULATE CURRENT IF THERE ARE NOT PRESENT ANY AMMETER OR MULTIMMETER??????

1868


How to do bus bar short circuit calculation for 230KV/11kv, 60 MVA Substation?

4720


Why PS class CT is always preferred for Differential protection?

1601


What is the difference between AC and DC injection methods for rotor earth fault protection

2226


how much maximum load a 2 core (Single phase) 16mm aluminium wire can take ?

2640


What are the different types of transformers?

1163


how we explain parallel paths armature winding?

1957


The height to which the liquid in a tank to be maintained for a certain constant velocity?

1996


Please explain me abt PQ diagaram in the power sector.

2419


State kirchoff current law?

1086


how can we design robots

1950


Why 9KV surge arrester having 7.65KV of MCOV?

1576