what is the HT motor current setting (Motor protection relay)aganist FLA If the capacitor is connected in parallal to the motor to increase the P.F from 0.89 to 0.99. the setting is to be reduced. what is the formula for to calculate the current.(FLA - CALCULATED CURRENT!= )
1 8823what is the mechanism of operation of brushless dc motor why is it more wexpensive then ordinary permanent magnet motors
1 2064we know that dc motors are more superior then three phase induction motors in torque generation though they are not much used in industries why?
5 8273What are the reason of unbalanced secondary voltage of HT transformer 33kv/6.6kv ? Incomming voltage is balanced.33kv each secondary voltage 6.6 kv 6.4 kv 6.4 kv At no load conditions.
1 3948DO MEGGER TEST APPLIED ON SURGE ARRESTOR? IF YES THEN WHAT ARE THE ACCEPTED R VALUE REQUIRED FOR SURGE ARRESTORS FOR VOLTAGE LEVEL 11KV, 33KV
2 10320in small capacitor we use uf( micro farad) and in big quantity we used kvar. i want to know that in 1 kva how much will b uf(micru farad).
2 5494Post New Electrical Engineering Questions
How much minimum insulation required between 11kv/3.3kv transformer windings?
hi friend i am going too attend for hpcl in this month please help me by sending written test question papers i am in the stream of E.E.E
i need the curve duty cycle and amper for (150 kva @50% dyty cycle) transformer turn ratio :19 and vin 400
What are the different methodes for calculating the short circuit Current?
How to calculate the sag on transmission Lines.
RESPECCTED SIR/MADAM- I AM PRERING FOR SECTION ENGINEER (ELECTRICAL) RRB CHANDIGARH PLEASE SEND ME SOME PREVIOUS YEAR QUESTION PAPER OR MODEL PAPER.MY EXAM IS ON (30- NOVEMBER 2008).I AM VERY THANKFUL TO YOU. FROM- HARENDRA SINGH YADAV
as a electrical student why should i hire you?
I need bhel electrical test pattern & paper
HAI SENT HPCL APTITUDE QUESTION PAPER, MY EMAIL ID IS angus_eee04@rediffmail.com,angus_eee04@yahoo.com
what are the values of VRY,VYB,VBR,Vry,Vyb,Vbr,Vrn,Vyn,Vbn for Magenetic balance test of 100 KVA and 63 KVA Distribution transformer
why and how voltage sharing in transformer, during magnetic balance test ?
A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.
what is a reactive power? what is the relation with power factor?
please send previous exams question papers
I am shobana from Chennai. I am having my personal interview on 19th Dec at Chennai.kindly mail me the questions to mail id shobana.shanthi@gmail.com