in three pin plug 6 Amp. 220v AC rating. why earth pin diameter is higher than ohter two pin? what its purpose ?
6 9140Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.
HAL,
2028We have 90mX100m hangar with 16 no.of supporting pillar. It is required to provide power supply on all pillars. what is suggested earthing scheme for hangars.
HAL,
1996In a company the lines carrying 33KV but the load is below 10000Volts so we know that <11KV we can put 11KV lines but the lines are 33KV,..so how we can step down the voltage to 11KV with out erecting a substation
1 3033What is Icu and Ics and what is difference b/w them. please tell me how to calculate a size of a copper bar for a system or a breaker... reply on... king.arish@gmail.com would be waiting for a logical answer.
2458What is the basic principle of circuit breaker?.. I read that it works on electro-mechanical principle... Does it require both electric n magnetic conversion to act?
3 6419Post New Electrical Engineering Questions
We have received supplies of the ordered material. payments against the supplies also released. Where ST paid 4% against form C. Meanwhile it has been observed that 25% of material supplied was defective. Please suggest whether the issuance of C form from our side would be stopped till settlement of liabilities.
What is the function of electron gun used in crt?
How to calculate Temp from Resister from PT100 equation,
What is the Minimum winding resistance of motors ( small & big)? referance range
why is control bus bi-directional?
what happen if drive input fail momentry at 48.5 HZ frequency?
difine electrical ballast in HPSVL
What is a difference between indoor transformer and outdoor transformer of same rating
HOW TO SELECT THE COPPER CABLE SIZES OF MOTORS,TRANSFORMERS?
my UPS suddenly goes off and all panel light also blow off.This happens even main electric supply is not interrupted.After some time it automatically starts functioning normally.Batteries are new.
Explain marx circuit.
can i use 2000/5A Clamp meter to measure HT cable
State nyquist stability criterion.
what is the difference between gas group b and gas group c electrical equipment construction wise?
what is the physical connection of a analog i/p to a analog i/p module (ab plc)and through a analog o/p module(ab plc) to a analog o/p . and how all the process control by scada