Energy metering: On the property I am renting, the supply voltage is 2 x 110 volts. These 2 x phases enter a energy meter which then exit the meter to over head lines to my house. Question 1. The meter is single phase 240 volts but is being used as 2 x phase(2 x 110volt), is this acceptable? if not, please give me the reasons. The meter details are as follows: 60Hz 15amp Imax 100 amp Kd 3,6 Wh/R 1 fase 3 hilos Model FX 231. I think it was manufactured in Brasil From this meter, the cables run along over head aluminum conductors,I estimate the cross sectional area to be 25mm diameter, but the neutral is only about 10mm square diameter, which cover a distance of 170 meters and then terminate with an underground cable of 65 meter length, total length = 235 meters. There must be a huge voltage drop over this length. This line is protected with 2 x 200 amp aluminum fuses after the meter, there is no main switch in the distribution board. These 2 phases connect directly onto 2 busbars. Surely the neutral should be the same size as the conductors if not more? Question2. What are your thoughts about this installation, should there be better protection, is the neutral too small? During the night, the lights dim then brighten all the time, this cannot be good for my electrical appliances. In my home, I only have a small electric geyser and fridge, my stove works off gas. But when i use other appliances like the washing machine or microwave oven, the light dim. The internal wiring of this house is done with solid hard drawn copper wires and of course, they have to be under rated. I am a retired electrician by trade, but not on the metering and over head mains side, my experience is on the factory maintenance side of things. Your expertise on these matters will be greatly appreciated. Please inform me how to rectify or make any improvements Kind regards, my power bill is very expensive, so I need to know how to bring it lower. Kind regards, Brian
1 3445in a live circuit with a light bulb such that the bulb is off by a switch, is the light glows if the switch 2 terminals are both touched by a mouse?
1 3522how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
1922in an electronic tri vector meter when the current and voltage sequence changes ? what is the effect of phase sequence on recording of meter
L&T,
2231what is the difference between 3 phase 3wire &3phase 4 wire meter?what is the advantage of 3p3w over 3p4w?
1 17935how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating
24132 v/500amp/hr to 1.80vpc at 20 degree celsious 2v/5ooamp/hr to 1.75 vpc at 77degree farren .this is the capacity of a battery .what is the meaning of this . can i get a detailed explenation
2300Post New Electrical Engineering Questions
explain comutator action in detail.thanks
can i connect the two phases of scott connected transformer,if not why?
write encoder 17 pins details? pin a;b+, pin b;w+,..pin s & t. what is the meaning of b+, w+? explain;
what is the formula for efficiency of francis turbine and generator for hydropower? what is best way to select francis turbine and generator?
How to find out damper winding failure for synchronous machine?
How to design the earth grid for lightning protection in an industry
How do we calculate the Out put voltage of generator, after the excitation is being given?
how can calculate resistance box for 15 kw, 6 pole, RV-230, RA-42 motor
Explain the function and difference of Restricted earth fault, simple earth fault and sensitive earth fault with connection diagram.
why using transformer and thyristor switch in 3 phase apfc panel
What is star-delta transformer?
why +24 v and -48 v give to BTS? If -48v protect from surge then why we not use -24 v?
What are the advantages and disadvantages of closed-loop control system?
why are u join ntpc
How does cost of generation from hydropower plant compare with other sources of electricity?