Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

sir can you operated Transformer on frequency from that for which is design?

Kirloskar,

1 4377

sir what is the minimun earth resistance value of an industial bit and grid bit ? and Why?

Kirloskar,

1 5405

what is difference between power & distrubution transformer ?

3 7037

how did the differential relay work to protect the power transformer

4 11382

why do we have 230v a.c. as general voltage for domestic supply rather than others?

2 6618

In transmission line the line power loss only accured at resistance the inductance and capacitance wont consume power is it correct?

2 4767

What are the types of AMF(auto main failure) panel.

1 4424

sir, Is their any measuring unit of knoking? please explian?

Kirloskar,

1 1977

sir, why alternator output is connected to delta side in to generating transformer? any reasion?

Kirloskar,

3 7747

sir, Two different rating of generator going to connect parallel, can it set same DROOP or different. Why? Please explain

Kirloskar,

2 7272

Sir, why generating power plant operating at above 0.9 lag? detail explaination?

Kirloskar, L&T,

1 5731

generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...

1 2003

why grid frequency varry time to time?

2 5382

whats the reletion betweet flow,pressure,head,rpm and motor rating?

1 5165

whatis the test procedure for lightning arrester which was installed one year back. i want check it whether it is working or not.

1 4396


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

pls,send the previous year written test questions.

1985


sir i want previous entrance exam papers for written test

2235


PLS SEND THE RRB CHENNAI MODEL QUESTION PAPER my email id is ganesan98655@rediffmail.com

2094


I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?

3878


hi friend i am going too attend for hpcl in this month please help me by sending written test question papers i am in the stream of E.E.E

2048


A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.

1180


1)how to reduce the value of tan delta of trasformer and CB,bushing,CT&PT,CVT ? 2)how to reduce the resistance of CB contact and its operating time? 3)plz.....send me the project report on conditioning and monitoring of substation equipment on my email id (gusaiyogendra03@gmail.com)

2405


I HAVE BEEN SELECTED FOR APGENCO A.E(ELECTRICAL) 2008.HOW MUCH WEIGHTAGE FOR INTERVIEW AND WRITTEN TEST.HOW I HAVE TO PREPARE. PLEASE GIVE INFORMATION IF U KNOW.WHAT ABT G.D THIS TIME.CALL RATIO 1:2

2983


all the technical question with answers pleas send your email id ramar_eee@yahoo.com

2106


please send me jindal previous aptitude and technical question and answer.my email id is deep_raj@live.com

2047


What is the basic principal, by which DC voltage level is increased more than the supplied AC voltage during conversion. As upto AC level it is contorrled by firing anlge but after maximum level how is it possible.Please clear picture. OR we have to supply the higher level AC?

2040


Draw a SLD for main panel for school having connected load of 1200kw and emergency generator 200kw.also show the increase of additional load of chiller 225kw in the lv panel indicating meter postion size of transformer ,cables and capacitor bank.

1053


How to calculate the sag on transmission Lines.

3113


hi this is hema can anyone mail me previous years questions for the APPSC-A.E.E (in electrical stream.) ......thank u.

1991


I am going to appear RRB Sr. Section Engineer Exam, Electrical. Can you send me previous year questions of RRB Electrical engineer. specially Section Engineer questions. my email id is likerahulworld@gmail.com

1893