Electrical Engineering Interview Questions
Questions Answers Views Company eMail

Why is a thicker conductor necessary to carry a current in A.C.as compared to D.C. ?

1 3978

Then what do you call a transformer that is installed on the ground?"

1 3507

why does connected a indutor with mnsformeretering core of current transformer ?

1637

how to set the transformer differential relay

Divis Laboratories,

1 5830

in 132 kv substation ligtning arrestor(120 kv) connected to line. but line voltage comes to 132 kv, it operate or not???

Divis Laboratories,

4 14709

voltage of a ckt is measured by volt meter having an input impedence camparable with the out put impedance of the ckt Eror caused is 1. Gross Error 2. Errors due to lloading effect

GATE,

2 3240

when the control mechanism is present for an ammeter(1-10A) and 1A current is apllied what will be the reading of the meter?

GATE,

2 3603

Relay setting for earth fault of reciprocating and centrifugal compressor motor feeder.Setting will be different or same?

Reliance,

1 3310

what is cathodic protaction?

1482

The error in a single phase energy meter where pressure coil lags behind applied voltage by 88 degrees and pf is 1) upf 2).5lag

GATE,

1 3915

why we use 20 KV, 10KA LA on 22 KV Line

2 5973

WHY TRANSFORMER RATING IS MENTIONED IN KVA RATHER THAN KW

5 8307

HOW SKIN EFFECT REDUCE THE CROSS SECTION OF THE CONDUCTOR

2 4473

What is eddy current & eddy current loss ?

2 6521

how to avoid Saturation in C.T?

1564


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

Iwould like to know barc interview questions

2645


How we select the vector group of 3phase power transformer?

1979


what is meant by moulded case circuit breaker ?

1705


WHY EXCITER PHASE SEQUENCE ARE OPPOSITE THAN STATOR SUPPLY PHASE SEQUENCE IN SYNCHRONOUS MOTOR >

1434


What is ignition module of a CAT Gas Genset G-3508 Engine, Alternator SR4B Series. HOw its checked for correct functioning.Is it repiarable or replacable?

1718






what is the earth current,reverse power,electrical trip generator short circuit,low voltage, high voltage please discribe me

1641


what about electrical pannel.? What is meant by plc pannel.?

1865


What is marx circuit?

647


why surge protectetor work explain with the help of circut diagram?

1525


what are the different kind of cables used for transmissions?

712


explain the types of drives

1550


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

1573


if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit

1401


Why HT 11 KV Slipring Motors are connected in star ?

1761


what is plunger and what's the use of it in motor alignment?

2003