If we touch the Capacitor terminals you feel shock after the capacitor was put in operation and not in case of inductor though both are energy storage elements.why?
HAL,
4 10358When calculation of fault current and fault Kva is to be done,why always we use per unit value and why we consider the base kva?
1903why we did not get shock by touching +ve OR -ve busbar (Which are going to supply cell voltage) of Rectifier- Tranformer in electrolysis plant?
4 7277why we did not get shock by touching nuetral of any single phase supply of a electrical equipement?
6 12160can transformer work on dc or not?if we increase the inductance of transformer can it happen to work on dc?
1 38821)we r having one problem .one dry type transformer(6.6KV/433V)is taking high magnetizing current on delta connected HV side of "U" phase when compared to other two phases.could any body tell the reason why it is happening? 2)why CT secondary side protection core has got higher winding resistance when compared to that of metering core of same CT?
2 5245Post New Electrical Engineering Questions
WHY NUTRAL GROUND SYSTEM USED IN 33KV SYSTEM
we have a lot of model of rectifier but thyristor rectifier is the most rectifier that use in power system. Do you know why this rectifier is used?
what is the range of maximum DOL and SDS can be use for pump and fan application
What should be the length of transmission line so that we can see/obtain the full sine wave of voltage??
what happen if the parallel generator phase angle shift by 1 degree in manual mode
What is Load sharing of Transformer ?
In the magnetic fluxes, what is the role of armature reaction?
what is cause of static electricity? I experience shock when i touch metal equipment in a room ,furher check shows earth leakage showing 80ma at the DB near to the 400 MCCB?
How does zener phenomenon differ from avalanche breakdown?
Why do we need a separate control desk & PLC control panel in Boiler plant or coal handling plant? Can we provide cost effective Control desk cum PLC panel. Is there is an specific need for control desk.. kindly advice.
how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec.
Explain about p.t?
What happens if the negative to earth voltage is greater than positive to earth voltage in the battery of substation?
Why frame of the motor is specified?. If we mention KW and voltage level,automatically frame is decided or separately frame is compulsory to mention?.
what are the standard IR values should be of R-E, Y-E, B-E, R-Y, Y-B, B-R of VCB in closed condition and in open condition for 500KVA & 1000KVA transformers. and what is the acceptable range when tested by 5000V megger.